Literature DB >> 29501858

Comparative sensitivity and inhibitor tolerance of GlobalFiler® PCR Amplification and Investigator® 24plex QS kits for challenging samples.

Kyleen Elwick1, Carrie Mayes2, Sheree Hughes-Stamm2.   

Abstract

In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DNA typing; GlobalFiler® PCR Amplification kit; Human identification; Investigator® 24plex QS kit; PCR inhibitors; Short tandem repeats

Mesh:

Year:  2018        PMID: 29501858     DOI: 10.1016/j.legalmed.2018.01.006

Source DB:  PubMed          Journal:  Leg Med (Tokyo)        ISSN: 1344-6223            Impact factor:   1.376


  2 in total

1.  Validation of the Investigator 24plex QS Kit: a 6-dye multiplex PCR assay for forensic application in the Chinese Han population.

Authors:  Ruiyang Tao; Chong Chen; Xiang Sheng; Ruocheng Xia; Xiaochun Zhang; Jingyi Zhang; Zihao Yang; Suhua Zhang; Chengtao Li
Journal:  Forensic Sci Res       Date:  2019-12-06

2.  Assessment of impact of DNA extraction methods on analysis of human remain samples on massively parallel sequencing success.

Authors:  Xiangpei Zeng; Kyleen Elwick; Carrie Mayes; Maiko Takahashi; Jonathan L King; David Gangitano; Bruce Budowle; Sheree Hughes-Stamm
Journal:  Int J Legal Med       Date:  2018-10-19       Impact factor: 2.686

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.