Literature DB >> 29498941

Ultrasound-Guided Laryngeal Air Column Width Difference as a New Predictor for Postextubation Stridor in Children.

Doaa El Amrousy1, Mohamed Elkashlan2, Nagat Elshmaa2, Ahmed Ragab3.   

Abstract

OBJECTIVES: To assess the efficacy of ultrasound-guided laryngeal air column width difference in predicting postextubation stridor in children.
DESIGN: Prospective observational study.
SETTING: Single, tertiary care pediatric hospital. PATIENTS: This study was carried out at PICU and surgical ICU, Tanta University Hospital on 400 ventilated children between January 2015 and May 2017. Patients who received mechanical ventilation and met criteria for a weaning trial were included. INTERVENTION: Laryngeal ultrasound and cuff leak test.
MEASUREMENTS AND MAIN RESULTS: Ultrasound-guided laryngeal air column width and cuff leak test were measured before extubation. Laryngeal air column width is the width of air between the vocal cords seen by laryngeal ultrasonography. Laryngeal air column width difference is the width difference of air column passed through vocal cords with the balloon cuff inflated and deflated. Three-hundred fifty six patients (89%) had no postextubation stridor, whereas 44 patients (11%) developed postextubation stridor. Postextubation stridor was associated with younger age, less weight, female gender, prolonged duration of intubation, and ICU stay (p < 0.05). Both laryngeal air column width difference and cuff leak test showed significant decrease (p < 0.05) in patients with postextubation stridor in comparison with no postextubation stridor patients. Receiver operating characteristics curve analysis showed that laryngeal air column width difference at cutoff point of less than 0.8 mm gave a sensitivity of 93%, specificity of 86%, and accuracy of 91%, whereas cuff leak test at less than 11% yielded a sensitivity of (61%), specificity of (53%), and accuracy of (59%) for predicting postextubation stridor.
CONCLUSIONS: Laryngeal air column width difference measurement may serve as a simple reliable noninvasive method for predicting postextubation stridor in children.

Entities:  

Mesh:

Year:  2018        PMID: 29498941     DOI: 10.1097/CCM.0000000000003068

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  3 in total

Review 1.  The Value of Lung Ultrasound Score in Neonatology.

Authors:  Haifeng Zong; Zhifeng Huang; Jie Zhao; Bingchun Lin; Yongping Fu; Yanqing Lin; Peng Huang; Hongyan Sun; Chuanzhong Yang
Journal:  Front Pediatr       Date:  2022-05-11       Impact factor: 3.569

Review 2.  Point-of-Care Ultrasound in the Pediatric Intensive Care Unit.

Authors:  Luke Burton; Vidit Bhargava; Michele Kong
Journal:  Front Pediatr       Date:  2022-02-01       Impact factor: 3.418

3.  The difficult removal of tracheal tube after general anesthesia: A case report.

Authors:  Man Li; YaLan Yan; PeiYu Li; Lan Zhang
Journal:  Medicine (Baltimore)       Date:  2022-10-07       Impact factor: 1.817

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.