PURPOSE: The aim of this study is to present a feasibility study to evaluate and compare a self-constructed, digital-based tangent scale using the Harms tangent screen test for the examination of patients' strabismus angles.
METHODS: The documented strabismus angles of 10 patients were measured at nine gaze-positions and compared using the Harms tangent screen test (Harms Screen) and a self-constructed digital screen test (Digital Screen). The primary outcome is the difference in the measured angles between both methods. Secondary outcomes include the duration of the examinations and the diagnostic conclusion based on the results of the measurements.
RESULTS: The datasets from 10 of 13 patients were used for comparisons (median age 52 years; females 5; males 5). All measurements showed a mean of 1.77° (SD 2.95°) in horizontal deviations and 1.11° (SD 2.23°) in vertical deviations. The two methods showed differences (> 5°) in 12 cases (13.3%) for horizontal angle measurements and in four cases (4.4%) for vertical angle measurements. The median examination time was 238 s (range 60-430 s) for the Harms Screen and 150 s (range 120-600 s) for the Digital Screen tests. The diagnostic conclusions were identical for both methods.
CONCLUSIONS: The feasibility of the experimental digital setup in principle is shown. Despite some deviations in the measured strabismus angles, the resulting diagnosis of the paresis was identical. The new method showed a reduction of examination time.

Entities:  

Keywords:  Ocular deviations; Strabism testing; Strabismus angle; Tangent scales

Mesh:

Year:  2018        PMID: 29497810     DOI: 10.1007/s00417-018-3938-4

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  11 in total

Review 1.  Automated measurement of strabismic deviation.

Authors:  C Schiavi; M Orciuolo
Journal:  Curr Opin Ophthalmol       Date:  1992-12       Impact factor: 3.761

2.  The harms tangent screen test.

Authors:  Mariette Tyedmers; Gill Roper-Hall
Journal:  Am Orthopt J       Date:  2006

Review 3.  Strabismus.

Authors:  Kammi B Gunton; Barry N Wasserman; Caroline DeBenedictis
Journal:  Prim Care       Date:  2015-07-07       Impact factor: 2.907

4.  Postoperative binocularity in adults with longstanding strabismus.

Authors:  B J Kushner; G V Morton
Journal:  Ophthalmology       Date:  1992-03       Impact factor: 12.079

Review 5.  Impact of strabismus surgery on health-related quality of life in adults.

Authors:  Kammi B Gunton
Journal:  Curr Opin Ophthalmol       Date:  2014-09       Impact factor: 3.761

Review 6.  [Early detection and treatment of strabismus].

Authors:  Daniel Mojon
Journal:  Ther Umsch       Date:  2016

7.  [The tangent scala according to Harms].

Authors:  G Mackensen
Journal:  Buch Augenarzt       Date:  1966

8.  Changes in the functional binocular status of older children and adults with previously untreated infantile esotropia following late surgical realignment.

Authors:  Anthony David Neil Murray; Jane Orpen; Carolyn Calcutt
Journal:  J AAPOS       Date:  2007-02-15       Impact factor: 1.220

9.  Binocular field expansion in adults after surgery for esotropia.

Authors:  B J Kushner
Journal:  Arch Ophthalmol       Date:  1994-05

Review 10.  Strabismus surgery for adults: a report by the American Academy of Ophthalmology.

Authors:  Monte D Mills; David K Coats; Sean P Donahue; David T Wheeler
Journal:  Ophthalmology       Date:  2004-06       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.