| Literature DB >> 29497658 |
Maiko Hasegawa-Moriyama1, Kohei Godai1, Tomotsugu Yamada1, Akira Matsunaga1, Yuichi Kanmura1.
Abstract
Regional cerebral oxygen saturation (rSO2) and the bispectral index (BIS) are used to detect cerebral perfusion abnormalities. However, whether rSO2 and BIS values change during ligation of the internal jugular vein (IJV) is unknown. We report a case in which BIS values were decreased, despite increased rSO2 during ligation of the IJV. A 72-year-old man was diagnosed with metastasis of renal cancer to the thyroid associated with tumor embolism in the right IJV. Thyroidectomy with total laryngectomy was performed. After right IJV ligation, right rSO2 was increased from 73 to 78 %, while the right BIS value was decreased from 40 to 27. Contralateral rSO2 and BIS values were unchanged. Right rSO2 and BIS values returned to pre-ligation values in 10 min. Ligation of the IJV might increase cerebral blood flow and ipsilateral rSO2. Physicians should use BIS values with caution during IJV ligation because a sudden decrease in the BIS value is not always associated with cerebral hypoperfusion.Entities:
Keywords: Bispectral index; Internal jugular vein; Regional saturation of oxygen
Year: 2016 PMID: 29497658 PMCID: PMC5818720 DOI: 10.1186/s40981-015-0027-0
Source DB: PubMed Journal: JA Clin Rep ISSN: 2363-9024
Fig. 1Anesthesia record. Hemodynamic parameters, regional cerebral oxygen saturation (rSO2), and the bispectral index (BIS) during general anesthesia are shown. SpO2, pulse oximetric oxygen saturation; MAP, mean arterial pressure; HR, heart rate; Sev, sevoflurane; DOA, dopamine
Fig. 2rSO2 and BIS values after ligation of the IJV. Changes in regional cerebral oxygen saturation (rSO2) and bispectral index (BIS) 10 min after the internal jugular vein (IJV) ligation are shown
Additional data of BIS values after ligation of the IJV. Changes in suppression ratio (SR), spectral edge frequency 95 (SEF95), electromyography (EMG) and signal quality index (SQI) 10 min after the internal jugular vein (IJV) ligation are shown
| Minutes after IJV ligation | SR (Left, %) | SEF95 (Left, Hz) | EMG (Left, dB) | SQI (Left, %) | SR (Right, %) | SEF95 (Right, Hz) | EMG (Right dB) | SQI (Right, %) |
|---|---|---|---|---|---|---|---|---|
| 1 | 0 | 12.8 | 24.7 | 94.9 | 0 | 12.3 | 25.4 | 94.9 |
| 2 | 0 | 10.4 | 25.1 | 87.8 | 0 | 10.2 | 26.4 | 82.1 |
| 3 | 0 | 10.4 | 24.7 | 62.2 | 0 | 10.5 | 24.9 | 59.6 |
| 4 | 0 | 8.6 | 24.8 | 55.1 | 0 | 8.2 | 24.8 | 55.1 |
| 5 | 0 | 8.2 | 24.8 | 94.2 | 0 | 7.5 | 24.6 | 94.9 |
| 6 | 0 | 9.2 | 24.7 | 83.3 | 0 | 8.5 | 24.9 | 82.1 |
| 7 | 0 | 8.2 | 29.4 | 84 | 0 | 6.9 | 33.9 | 78.2 |
| 8 | 0 | 8.4 | 24.9 | 80.8 | 0 | 7.8 | 25.4 | 79.5 |
| 9 | 0 | 9.9 | 24.8 | 69.2 | 0 | 10 | 24.8 | 66.7 |
| 10 | 0 | 10.6 | 24.4 | 91.7 | 0 | 10.7 | 24.5 | 82.7 |