Literature DB >> 29494992

Reducing artifacts of gadoxetate disodium-enhanced MRI with oxygen inhalation in patients with prior episode of arterial phase motion: intra-individual comparison.

Tomohiro Namimoto1, Kie Shimizu2, Masataka Nakagawa2, Yoko Kikuchi2, Masafumi Kidoh2, Seitaro Oda2, Takeshi Nakaura2, Daisuke Utsunomiya2, Yasuyuki Yamashita2.   

Abstract

PURPOSE: To determine whether oxygen inhalation reducing artifacts in patients with previous transient severe motion (TSM) on gadoxetate-disodium-enhanced MRI.
MATERIALS AND METHODS: Fifty-one patients with TSM on previous gadoxetate-disodium-enhanced MRI (Baseline examination) were evaluated. Image quality in the examination with oxygen inhalation (Oxygen examination) and that in Baseline examination and the examination before Baseline examination without oxygen inhalation (Past examination) were qualitatively compared in dynamic study.
RESULTS: Image quality was significantly higher in Oxygen examination than Baseline examination in arterial phase, but there was no statistical difference between Baseline and Past examinations.
CONCLUSION: Oxygen inhalation improved image quality in patients with a prior episode of arterial phase TSM.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Artifact; Dynamic study; Gadoxetate disodium; Liver; Magnetic resonance imaging

Mesh:

Substances:

Year:  2018        PMID: 29494992     DOI: 10.1016/j.clinimag.2018.01.020

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  3 in total

1.  Gadoxetate disodium-related event during image acquisition: a prospective multi-institutional study for better MR practice.

Authors:  Marie-Luise Kromrey; Masatoshi Hori; Satoshi Goshima; Kazuto Kozaka; Tomoko Hyodo; Yuko Nakamura; Akihiro Nishie; Tsutomu Tamada; Tatsuya Shimizu; Akihiko Kanki; Utaroh Motosugi
Journal:  Eur Radiol       Date:  2019-07-23       Impact factor: 5.315

Review 2.  Gadoxetate-Enhanced MRI as a Diagnostic Tool in the Management of Hepatocellular Carcinoma: Report from a 2020 Asia-Pacific Multidisciplinary Expert Meeting.

Authors:  Cher Heng Tan; Shu-Cheng Chou; Nakarin Inmutto; Ke Ma; RuoFan Sheng; YingHong Shi; Zhongguo Zhou; Akira Yamada; Ryosuke Tateishi
Journal:  Korean J Radiol       Date:  2022-05-09       Impact factor: 7.109

3.  Respiratory motion artefacts in Gd-EOB-DTPA (Primovist/Eovist) and Gd-DOTA (Dotarem)-enhanced dynamic phase liver MRI after intensified and standard pre-scan patient preparation: A bi-institutional analysis.

Authors:  Christian Wybranski; Florian Siedek; Robert Damm; Angelos Gazis; Ortrud Wenzel; Stefan Haneder; Thorsten Persigehl; Susanne Steinhauser; Maciej Pech; Frank Fischbach; Katharina Fischbach
Journal:  PLoS One       Date:  2020-03-20       Impact factor: 3.240

  3 in total