Literature DB >> 29494942

A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media.

Hamza Badry1, Lhoucine Oufni2, Hmad Ouabi3, Hideo Hirayama4.   

Abstract

In this study, the dosimetric characterization for The BEBIG 60Co High Dose Rate (HDR) brachytherapy source model Co0.A86 was investigated and the validity of the EGS5 Monte Carlo code to reproduce the dosimetric parameters in water phantom was checked. In addition, the dose distribution for different tissue phantoms was calculated. The BEBIG 60Co HDR brachytherapy source was modeled using EGS5 Monte Carlo simulation code. A description of the source design, geometry and materials used in this work were provided. According to the update TG43-U1 formalism of AAPM, the air kerma strength, the dose rate constant, 2D rectangular dose distribution in water were calculated, moreover, the results of the radial dose function were obtained in water and different tissue phantoms; bone, lung, adipose tissue, breast and muscle. The obtained results were tabulated and presented in graphical formats for the comparison with available data. The calculated value of the air kerma strength of this study, 3.0419 U Bq-1, agree well with that of the other Monte Carlo calculation. The 2D look-up along-away rectangular dose were obtained in water, the results were similar to the published data for all distances larger than 1 cm, for the distances near to the source region on the transversal source axis small differences are apparent. The radial dose function were presented in graphical format for the comparison between the dose distribution in water and different tissue phantoms. The EGS5 results obtained in this study shows good consistency with the published data for the dosimetric parameters of the of the BEBIG 60Co HDR brachytherapy source. It seems that the radial dose function calculated in water differed in tissue phantoms due to the atomic composition and densities for media that are not taken account by the TG43-U1 formalism.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  (60)Co; Brachytherapy; Dose; Monte Carlo

Year:  2018        PMID: 29494942     DOI: 10.1016/j.apradiso.2018.02.016

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  4 in total

Review 1.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

2.  Monte Carlo dosimetry for a new 32P brachytherapy source using FLUKA code.

Authors:  Razieh Rajabi; Payvand Taherparvar
Journal:  J Contemp Brachytherapy       Date:  2019-02-28

3.  BEBIG 60Co HDR brachytherapy source dosimetric parameters validation using GATE Geant4-based simulation code.

Authors:  Musa Joya; Hassan Ali Nedaie; Ghazale Geraily; Mahdi Ghorbani; Peyman Sheikhzadeh; Mahmud Naraqi Arani
Journal:  Heliyon       Date:  2022-03-27

Review 4.  Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer.

Authors:  Aiping Wen; Xianliang Wang; Bingjie Wang; Chuanjun Yan; Jingyue Luo; Pei Wang; Jie Li
Journal:  Cancers (Basel)       Date:  2022-09-29       Impact factor: 6.575

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.