Role of paediatric assist device in bridge to transplant.

Roland Hetzer1, Mariano Francisco Del Maria Javier1, Eva Maria Delmo Walter2.   

Abstract

BACKGROUND: While heart transplantation has gained recognition as the gold standard therapy for advanced heart failure, the scarcity of donor organs has become an important concern. The evolution of surgical alternatives such as ventricular assist devices (VADs), allow for recovery of the myocardium and ensure patient survival until heart transplantation becomes possible. This report elaborates the role of VADs as a bridge to heart transplantation in infants and children (≤18 years old) with end-stage heart failure.
METHODS: A retrospective review of the medical records of 201 heart transplant recipients between May 1986 and September 2014 identified 78 children [38.8%; mean age 7.2 (7.8±6.0) years old; IQR: 2.6-11.8 years] with advanced heart failure who were supported with a VAD [left VAD (LVAD) =21; biventricular VAD (BVAD) =57] as a bridge to heart transplantation. Fourteen (17.9%) patients were less than 1 year old; 15 (19.2%) children had a cardiac arrest and underwent cardiopulmonary resuscitation, with 7 of these patients also requiring extracorporeal membrane oxygenation (ECMO) support prior to implantation of a VAD. The aetiology of heart failure was primarily cardiomyopathy (dilative, restrictive from endocardial fibrosis, idiopathic or toxic-induced), reported in 56 (71.8%) patients. The VADs employed were primarily Berlin Heart EXCOR® (n=63), HeartWare (n=13), Berlin Heart INCOR® (n=1), and Toyobo (n=1).
RESULTS: Mean duration of VAD support was 59 (133.37±191.57) days (range, 1-945 days; IQR: 23-133 days) before a donor heart became available. The primary complication encountered while patients were being bridged to transplant was mediastinal bleeding (7.8%). The main indication for pump exchanges was thrombus formation in the valves. There was no incidence of technical failure of the blood pump or driving system components. Skin infections around the cannulae occurred in 2.5%. Adverse neurological symptoms (thromboembolism 11.1%, cerebral haemorrhage 3.6%) that occurred did not have any permanent neurological sequelae that could be detected on clinical examination in this study. Mean duration of follow-up was 9.4 (10.3±7.6) years (IQR: 3.74-15.14 years). Cumulative survival rates of patients bridged to transplantation with VAD were 93.6%±2.8%, 84.6%±4.1%, 79.1%±4.7%, 63.8%±6.2%, 61.6%±7.1%, and 52.1%±9.3% at 30 days, 1, 5, 10, 15 and 20 years, respectively. There was no statistically significant difference (P=0.79) in survival rates of patients bridged to heart transplantation with VAD compared to those who underwent primary heart transplantation. Post-transplant survival rates stratified according to the type of VAD implanted and number of ventricles supported were not statistically different (P=0.93 and 0.73, respectively). In addition, post-transplant survival rates were not significantly different when age, gender and diagnosis were adjusted for. Furthermore, no statistically significant difference was found when post-transplant survival rates of children who had episodes of rejection were compared to those who did not have episodes of rejection.
CONCLUSIONS: The results in this series demonstrate that VADs satisfactorily support paediatric patients with advanced heart failure from a variety of aetiologies until heart transplantation. The data further suggests that patients bridged with VADs have comparable long-term post-transplant survival as those undergoing primary heart transplantation.

Entities:  

Keywords:  Ventricular assist device (VAD); bridge to transplantation; dilative cardiomyopathy; end-stage congenital heart disease (CHD); myocarditis; orthotopic heart transplantation; paediatrics

Year:  2018        PMID: 29492386      PMCID: PMC5827126          DOI: 10.21037/acs.2018.01.03

Source DB:  PubMed          Journal:  Ann Cardiothorac Surg        ISSN: 2225-319X


  51 in total

1.  A decade of pediatric mechanical circulatory support before and after cardiac transplantation.

Authors:  Jonathan M Chen; Marc E Richmond; Kevin Charette; Hiroo Takayama; Mathew Williams; Lisa Gilmore; Alejandro Garcia; Linda J Addonizio
Journal:  J Thorac Cardiovasc Surg       Date:  2011-12-03       Impact factor: 5.209

Review 2.  Paediatric mechanical circulatory support with Berlin Heart EXCOR: development and outcome of a 23-year experience.

Authors:  Roland Hetzer; Friedrich Kaufmann; Eva Maria Delmo Walter
Journal:  Eur J Cardiothorac Surg       Date:  2016-02-22       Impact factor: 4.191

3.  Ventricular assist device (VAD) for children: in vitro and in vivo evaluation.

Authors:  Y Taenaka; H Takano; T Nakatani; M Umezu; T Tanaka; T Akutsu; Y Naito; H Manabe
Journal:  Trans Am Soc Artif Intern Organs       Date:  1984

4.  Bridging children of all sizes to cardiac transplantation: the initial multicenter North American experience with the Berlin Heart EXCOR ventricular assist device.

Authors:  David L S Morales; Christopher S D Almond; Robert D B Jaquiss; David N Rosenthal; David C Naftel; M Patricia Massicotte; Tilman Humpl; Mark W Turrentine; James S Tweddell; Gordon A Cohen; Robert Kroslowitz; Eric J Devaney; Charles E Canter; Francis Fynn-Thompson; Olaf Reinhartz; Michiaki Imamura; Nancy S Ghanayem; Holger Buchholz; Sarah Furness; Robert Mazor; Sanjiv K Gandhi; Charles D Fraser
Journal:  J Heart Lung Transplant       Date:  2011-01       Impact factor: 10.247

5.  Rotary Blood Pumps as Long-Term Mechanical Circulatory Support: A Review of a 15-Year Berlin Experience.

Authors:  Roland Hetzer; Friedrich Kaufmann MEng; Evgenij Potapov; Thomas Krabatsch; Eva Maria Delmo Walter
Journal:  Semin Thorac Cardiovasc Surg       Date:  2016-01-12

6.  Noninvasive monitoring of cardiac allograft rejection by intramyocardial electrogram recordings.

Authors:  H Warnecke; S Schüler; H J Goetze; G Matheis; U Süthoff; J Müller; U Tietze; R Hetzer
Journal:  Circulation       Date:  1986-11       Impact factor: 29.690

7.  Daily noninvasive rejection monitoring improves long-term survival in pediatric heart transplantation.

Authors:  R Hetzer; E V Potapov; J Müller; M Loebe; M Hummel; Y Weng; H Warnecke; P E Lange
Journal:  Ann Thorac Surg       Date:  1998-10       Impact factor: 4.330

8.  Circulatory support with pneumatic paracorporeal ventricular assist device in infants and children.

Authors:  R Hetzer; M Loebe; E V Potapov; Y Weng; B Stiller; E Hennig; V Alexi-Meskishvili; P E Lange
Journal:  Ann Thorac Surg       Date:  1998-11       Impact factor: 4.330

9.  Mechanical left ventricular support as a bridge to cardiac transplantation in childhood.

Authors:  H Warnecke; F Berdjis; E Hennig; P Lange; D Schmitt; M Hummel; R Hetzer
Journal:  Eur J Cardiothorac Surg       Date:  1991       Impact factor: 4.191

10.  State of the art in paediatric heart transplantation: the Berlin experience.

Authors:  Roland Hetzer; Yuguo Weng; Eva Maria Delmo Walter
Journal:  Eur J Cardiothorac Surg       Date:  2012-11-25       Impact factor: 4.191

View more
  5 in total

1.  Surgical strategies for the management of end-stage heart failure in infants and children: A 15-year experience with a patient-tailored approach.

Authors:  Matteo Ponzoni; Anna C Frigo; Biagio Castaldi; Alessia Cerutti; Giovanni Di Salvo; Vladimiro L Vida; Massimo A Padalino
Journal:  Artif Organs       Date:  2021-09-12       Impact factor: 2.663

2.  Heart failure in the young: Insights into myocardial recovery with ventricular assist device support.

Authors:  Eva Maria Javier Delmo; Mariano Francisco Del Maria Javier; Dietmar Böthig; Andre Rüffer; Robert Cesnjevar; Michael Dandel; Roland Hetzer
Journal:  Cardiovasc Diagn Ther       Date:  2021-02

3.  Reversal of pulmonary hypertension in paediatric patients with restrictive cardiomyopathy.

Authors:  Johanna Schlein; Julia Riebandt; Günther Laufer; Daniel Zimpfer
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-29

4.  Evidence for synergy between sarcomeres and fibroblasts in an in vitro model of myocardial reverse remodeling.

Authors:  Shi Shen; Lorenzo R Sewanan; Stuart G Campbell
Journal:  J Mol Cell Cardiol       Date:  2021-05-14       Impact factor: 5.763

5.  Methods for determination of stagnation in pneumatic ventricular assist devices.

Authors:  Damian Obidowski; Piotr Reorowicz; Dariusz Witkowski; Krzysztof Sobczak; Krzysztof Jóźwik
Journal:  Int J Artif Organs       Date:  2018-08-03       Impact factor: 1.595

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.