Literature DB >> 29491528

Reply to Grocott HP, regarding their comment on 'Jet insufflator for cannot intubate cannot ventilate situation: An Indian Jugaad'.

Ketan Sakharam Kulkarni1, Nandini Malay Dave1, Priyanka Pradip Karnik1, Madhu Garasia1.   

Abstract

Entities:  

Year:  2018        PMID: 29491528      PMCID: PMC5827489          DOI: 10.4103/ija.IJA_33_18

Source DB:  PubMed          Journal:  Indian J Anaesth        ISSN: 0019-5049


× No keyword cloud information.
Sir, We thank Dr. Grocott for the insightful comments regarding our frugal innovation of jet insufflator for cannot intubate cannot ventilate situation.[1] Dr. Grocott suggests that the new commercially available device, the Ventrain® (Ventinova Medical B. V., Eindhoven, The Netherlands) exploits the Hagen–Poiseuille law for both jet inspiration as well as active expiration. The Hagen–Poiseuille law comments on the flow characteristics of a fluid or gas. The active expiration occurring in Ventrain is according to Bernoulli's theorem.[2] Our device provides the possibility of expiration as a passive process, which is not available with jet ventilators like Manujet III. The availability of devices such as Ventrain, Rapid O2, Enk oxygen flow modulator and Manujet III is still limited in India. In a developing country like India where many anaesthesiologists work in low-resource settings, procuring such kind of equipment is difficult. Although the Ventrain® has withstood the evaluations of medical equipment regulatory agencies, the evidence supporting its safety is still limited. We have devised the equipment from existing resources without any major additional cost. We are aware of the need to conduct prospective studies to provide evidence for the use of our device. Cautious use of our equipment in 'cannot intubate cannot ventilate' situation may add to safety till sophisticated and cost-effective devices for such situations are made freely available in remote areas.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  2 in total

1.  Emergency ventilation with the Ventrain® through an airway exchange catheter in a porcine model of complete upper airway obstruction.

Authors:  Michiel W P de Wolf; Reiner Gottschall; Niels P Preussler; Markus Paxian; Dietmar Enk
Journal:  Can J Anaesth       Date:  2016-10-28       Impact factor: 5.063

2.  Jet Insufflator for cannot intubate cannot ventilate situation. An Indian Jugaad.

Authors:  Ketan Sakharam Kulkarni; Nandini Malay Dave; Priyanka Pradip Karnik; Madhu Garasia
Journal:  Indian J Anaesth       Date:  2017-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.