This paper describes our method to evaluate neonatal cerebral circulation in a semiquantitative way by transfontanellar pulsed Doppler ultrasonography. We defined three arterial (internal carotid, basilar, and anterior cerebral artery) and three venous (internal cerebral and internal jugular vein; sinus rectus) sites for measurement of peak systolic, end diastolic, and mean velocity. Reference values, intraindividual and interindividual variation are calculated for infants between 750 and 4000 g body weight. Among all possible measurements follow up of mean velocity of the internal carotid artery in an individual infant is most reliable.

Entities:  

Mesh:

Year:  1986        PMID: 2949140

Source DB:  PubMed          Journal:  Monatsschr Kinderheilkd        ISSN: 0026-9298            Impact factor:   0.323


  7 in total

1.  Pulsed Doppler sonographic measurement of normal values for the flow velocities in the intracranial arteries of healthy newborns.

Authors:  K H Deeg; T Rupprecht
Journal:  Pediatr Radiol       Date:  1989

2.  Duplex-scanning of the deep venous drainage in the evaluation of blood flow velocity of the cerebral vascular system in infants.

Authors:  P Winkler; K Helmke
Journal:  Pediatr Radiol       Date:  1989

3.  Alterations of intracranial pressure and cerebral blood flow velocity in healthy neonates and their implication in the origin of perinatal brain damage.

Authors:  H M Strassburg; K Bogner; H J Klemm
Journal:  Eur J Pediatr       Date:  1988-01       Impact factor: 3.183

4.  Acute and protracted effects of intratracheal surfactant application on internal carotid blood flow velocity, blood pressure and carbondioxide tension in very low birth weight infants.

Authors:  G Jorch; H Rabe; M Garbe; E Michel; L Gortner
Journal:  Eur J Pediatr       Date:  1989-08       Impact factor: 3.183

5.  Failure of autoregulation of cerebral blood flow in neonates studied by pulsed Doppler ultrasound of the internal carotid artery.

Authors:  G Jorch; N Jorch
Journal:  Eur J Pediatr       Date:  1987-09       Impact factor: 3.183

6.  Investigations of renal artery blood flow velocity in preterm and term neonates by pulsed Doppler ultrasonography.

Authors:  T Bömelburg; G Jorch
Journal:  Eur J Pediatr       Date:  1988-04       Impact factor: 3.183

7.  Age dependence of flow velocities in basal cerebral arteries.

Authors:  H Bode; U Wais
Journal:  Arch Dis Child       Date:  1988-06       Impact factor: 3.791