Literature DB >> 29490605

Polyplex System Versus Nucleofection for Human Skin Cell Transfection and Effect of Internal Ribosome Entry Site Sequence.

Natalia Yiset Becerra Colorado1,2, Claudia Marcela Arenas Gómez3, Maria Isabel Patiño Vargas1, Jean Paul Delgado Charris3, Carlos Enrique Muskus López4, Luz Marina Restrepo Múnera1.   

Abstract

Nonviral transfection has important implications on gene therapy because of its safety. In particular, polyfection and nucleofection are two widely used systems for nonviral gene delivery. Their potential depends on the transfection efficiency achieved, which is influenced in turn by the type of cells transfected and by the plasmid that carries the gene of interest. The efficiency of transfection by polyfection or nucleofection in human fibroblasts and keratinocytes was evaluated in this study. Transfections were performed with plasmids containing a gene of interest (human cathelicidin antimicrobial peptide) and two reporter genes (red or green fluorescent protein) that included or not an internal ribosome entry site (IRES). The efficiency was measured by flow cytometry in terms of percentage of cells expressing the reporter gene; viability of transfected cells was also evaluated. It was found that nucleofection was more efficient than polyplexes for transfecting fibroblasts, while no significant differences were found between both systems of transfection when applied to keratinocytes. Regarding the viability of fibroblasts after transfection, values were high in both systems. In contrast, keratinocytes were more sensitive to nucleofection. It was also noted that both types of cells decreased reporter gene expression when IRES sequence was located upstream of the reporter gene, suggesting a negative effect on the expression of this gene. These results confirm that the transfection efficiency depends on the type of cells and the system used.

Entities:  

Keywords:  IRES; fibroblast; keratinocytes; nonviral transfection; nucleofection; polyplexes

Mesh:

Substances:

Year:  2018        PMID: 29490605     DOI: 10.1089/ten.TEC.2017.0435

Source DB:  PubMed          Journal:  Tissue Eng Part C Methods        ISSN: 1937-3384            Impact factor:   3.056


  1 in total

1.  Improving Fibrin Hydrogels' Mechanical Properties, through Addition of Silica or Chitosan-Silica Materials, for Potential Application as Wound Dressings.

Authors:  Natalia Y Becerra; Luz M Restrepo; Yessika Galeano; Ana C Tobón; Luis F Turizo; Monica Mesa
Journal:  Int J Biomater       Date:  2021-06-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.