Literature DB >> 29489436

Patient radiation dose and fluoroscopy time during ERCP: a single-center, retrospective study of influencing factors.

Ekaterina Saukko1, Juha M Grönroos2,3, Paulina Salminen2,3, Anja Henner4, Miika T Nieminen5,6,7.   

Abstract

OBJECTIVES: Recently, both the number and the complexity with associated increased technical difficulty of therapeutic ERCP procedures have significantly increased resulting in longer procedural and fluoroscopy times. During ERCP, the patient is exposed to ionizing radiation and the consequent radiation dose depends on multiple factors. The aim of this study was to identify factors affecting fluoroscopy time and radiation dose in patients undergoing ERCP.
MATERIALS AND METHODS: Data related to patient demographics, procedural characteristics and radiation exposure in ERCP procedures (n = 638) performed between August 2013 and August 2015 was retrospectively reviewed and analyzed. Statistically significant factors identified by univariate analyses were included in multivariate analysis with fluoroscopy time (FT) and dose area product (DAP) as dependent variables. Effective dose (ED) was estimated from DAP measurements using conversion coefficient.
RESULTS: The factors independently associated with increased DAP during ERCP were age, gender, radiographer, complexity level of ERCP, cannulation difficulty grade, bile duct injury and biliary stent placement. In multivariate analysis the endoscopist, the complexity level of ERCP, cannulation difficulty grade, pancreatic duct leakage, bile duct dilatation and brushing were identified as predictors for a longer FT. The mean DAP, FT, number of acquired images and ED for all ERCP procedures were 2.33 Gy·cm2, 1.84 min, 3 and 0.61 mSv, respectively.
CONCLUSIONS: Multiple factors had an effect on DAP and FT in ERCP. The awareness of these factors may help to predict possible prolonged procedures causing a higher radiation dose to the patient and thus facilitate the use of appropriate precautions.

Entities:  

Keywords:  Cholangiopancreatography; endoscopic retrograde; fluoroscopy; multivariate analysis; radiation exposure; radiation protection

Mesh:

Year:  2018        PMID: 29489436     DOI: 10.1080/00365521.2018.1445774

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  3 in total

1.  Radiation protection effect of mobile shield barrier for the medical personnel during endoscopic retrograde cholangiopancreatography: a quasi-experimental prospective study.

Authors:  Kwang Hyun Chung; Young Sook Park; Sang Bong Ahn; Byoung Kwan Son
Journal:  BMJ Open       Date:  2019-03-20       Impact factor: 2.692

2.  The radiation environment of anaesthesiologists in the endoscopic retrograde cholangiopancreatography room.

Authors:  Bora Lee; Min-Soo Kim; Darhae Eum; Kyeong Tae Min
Journal:  Sci Rep       Date:  2019-06-24       Impact factor: 4.379

3.  Usefulness of an additional lead shielding device in reducing occupational radiation exposure during interventional endoscopic procedures: An observational study.

Authors:  Reiko Yamada; Yusuke Saimyo; Kyosuke Tanaka; Aiji Hattori; Yuhei Umeda; Naoki Kuroda; Junya Tsuboi; Yasuhiko Hamada; Yoshiyuki Takei
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

  3 in total