Literature DB >> 29488887

Novel predictors of mild paravalvular aortic regurgitation in SAPIEN 3 transcatheter aortic valve implantation.

Gilbert H L Tang1, Syed Zaid, Samuel R Schnittman, Hasan Ahmad, Ryan Kaple, Cenap Undemir, Tanya Dutta, Angelica Poniros, Joanne Bennett, Cheng Feng, Martin Cohen, Steven L Lansman.   

Abstract

AIMS: Paravalvular leak (PVL) remains an important issue in TAVI. The Edwards SAPIEN 3 (S3) valve has reduced PVL but in up to one third of patients mild leak remains. Our study aimed to identify predictors of mild PVL after TAVI with the S3 valve. METHODS AND
RESULTS: From October 2015 to May 2017, 122 consecutive patients underwent S3 TAVI for symptomatic severe aortic stenosis. Thirty-three patients with mild PVL on transthoracic echocardiography at 30-day follow-up were compared to 89 with none/trace PVL. Thirty-day mortality was 2.5% (n=3), with zero stroke and major vascular complications. There were no differences between the two groups in patient characteristics, annular and left ventricular outflow tract (LVOT) sizing, distribution and severity of annular calcification, valve implantation technique, post-dilatation and implant depth. Mild PVL was associated with higher annular eccentricity (p=0.04) and moderate-severe LVOT calcification (p=0.03). Independent predictors of mild PVL were LVOT eccentricity (OR 1.05 per % ellipticity, 95% CI: 1.02-1.09, p=0.005), discordant sizing (OR 3.08, 95% CI: 1.20-7.90, p=0.02) and three-leaflet calcification (OR 13.3, 95% CI: 2.66-66.7, p=0.002).
CONCLUSIONS: LVOT eccentricity and discordant sizing predict PVL after S3 TAVI. Further studies are needed to understand their mechanism and significance.

Entities:  

Mesh:

Year:  2018        PMID: 29488887     DOI: 10.4244/EIJ-D-18-00005

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  4 in total

1.  Early commercial experience with a newly designed balloon-expandable transcatheter heart valve: 30-day outcomes and implications of preprocedural computed tomography.

Authors:  Andreas Schaefer; Fabienne Plassmeier; Niklas Schofer; Lukas Vogel; Sebastian Ludwig; Yvonne Schneeberger; Matthias Linder; Till Demal; Moritz Seiffert; Stefan Blankenberg; Hermann Reichenspurner; Dirk Westermann; Lenard Conradi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-04-08

Review 2.  Left Ventricular Diastolic Dysfunction and Transcatheter Aortic Valve Replacement Outcomes: A Review.

Authors:  Seyed Hossein Aalaei-Andabili; Anthony A Bavry
Journal:  Cardiol Ther       Date:  2019-03-07

3.  Optimal Oversizing Index Depending on Valve Type and Leakage-Proof Function for Preventing Paravalvular Leakage after Transcatheter Aortic Valve Implantation.

Authors:  You-Jeong Ki; Jeehoon Kang; Hak Seung Lee; Mineok Chang; Jung-Kyu Han; Han-Mo Yang; Kyung Woo Park; Hyun-Jae Kang; Bon-Kwon Koo; Hyo-Soo Kim
Journal:  J Clin Med       Date:  2020-12-04       Impact factor: 4.241

4.  A meta-analysis of 1-year outcomes of transcatheter versus surgical aortic valve replacement in low-risk patients with severe aortic stenosis.

Authors:  Aaqib H Malik; Syed Zaid; Hasan Ahmad; Joshua Goldberg; Tanya Dutta; Cenap Undemir; Martin Cohen; Wilbert S Aronow; Steven L Lansman
Journal:  J Geriatr Cardiol       Date:  2020-01       Impact factor: 3.327

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.