Literature DB >> 29485284

Carbon Nanotube Strain Sensor Based Hemoretractometer for Blood Coagulation Testing.

Zida Li, Yize Wang, Xufeng Xue, Brendan McCracken, Kevin Ward, Jianping Fu.   

Abstract

Coagulation monitoring is essential for perioperative care and thrombosis treatment. However, existing assays for coagulation monitoring have limitations such as a large footprint and complex setup. In this work, we developed a miniaturized device for point-of-care blood coagulation testing by measuring dynamic clot retraction force development during blood clotting. In this device, a blood drop was localized between a protrusion and a flexible force-sensing beam to measure clot retraction force. The beam was featured with micropillar arrays to assist the deposition of carbon nanotube films, which served as a strain sensor to achieve label-free electrical readout of clot retraction force in real time. We characterized mechanical and electrical properties of the force-sensing beam and optimized its design. We further demonstrated that this blood coagulation monitoring device could obtain results that were consistent with those using an imaging method and that the device was capable of differentiating blood samples with different coagulation profiles. Owing to its low fabrication cost, small size, and low consumption of blood samples, the blood coagulation testing device using carbon nanotube strain sensors holds great potential as a point-of-care tool for future coagulation monitoring.

Entities:  

Keywords:  blood coagulation; carbon nanotube; clot retraction force; point-of-care diagnostics; strain sensor

Mesh:

Substances:

Year:  2018        PMID: 29485284      PMCID: PMC6223013          DOI: 10.1021/acssensors.7b00971

Source DB:  PubMed          Journal:  ACS Sens        ISSN: 2379-3694            Impact factor:   7.711


  20 in total

Review 1.  Perioperative systemic haemostatic agents.

Authors:  A M Mahdy; N R Webster
Journal:  Br J Anaesth       Date:  2004-07-26       Impact factor: 9.166

2.  Force field evolution during human blood platelet activation.

Authors:  Sarah Schwarz Henriques; Rabea Sandmann; Alexander Strate; Sarah Köster
Journal:  J Cell Sci       Date:  2012-05-11       Impact factor: 5.285

3.  Platelet retraction force measurements using flexible post force sensors.

Authors:  Xin M Liang; Sangyoon J Han; Jo-Anna Reems; Dayong Gao; Nathan J Sniadecki
Journal:  Lab Chip       Date:  2010-01-20       Impact factor: 6.799

4.  A cartridge based sensor array platform for multiple coagulation measurements from plasma.

Authors:  O Cakmak; E Ermek; N Kilinc; S Bulut; I Baris; I H Kavakli; G G Yaralioglu; Hakan Urey
Journal:  Lab Chip       Date:  2015-01-07       Impact factor: 6.799

5.  A Miniaturized Hemoretractometer for Blood Clot Retraction Testing.

Authors:  Zida Li; Xiang Li; Brendan McCracken; Yue Shao; Kevin Ward; Jianping Fu
Journal:  Small       Date:  2016-06-01       Impact factor: 13.281

6.  Mechanics and contraction dynamics of single platelets and implications for clot stiffening.

Authors:  Wilbur A Lam; Ovijit Chaudhuri; Ailey Crow; Kevin D Webster; Tai-De Li; Ashley Kita; James Huang; Daniel A Fletcher
Journal:  Nat Mater       Date:  2010-12-05       Impact factor: 43.841

7.  Magnetoelastic transducers for monitoring coagulation, clot inhibition, and fibrinolysis.

Authors:  Libby G Puckett; Jaime K Lewis; Aaron Urbas; Xiangdong Cui; Dayong Gao; Leonidas G Bachas
Journal:  Biosens Bioelectron       Date:  2005-03-15       Impact factor: 10.618

8.  Simple room temperature bonding of thermoplastics and poly(dimethylsiloxane).

Authors:  Vijaya Sunkara; Dong-Kyu Park; Hyundoo Hwang; Rattikan Chantiwas; Steven A Soper; Yoon-Kyoung Cho
Journal:  Lab Chip       Date:  2010-12-08       Impact factor: 6.799

9.  First-line therapy with coagulation factor concentrates combined with point-of-care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: a retrospective, single-center cohort study.

Authors:  Klaus Görlinger; Daniel Dirkmann; Alexander A Hanke; Markus Kamler; Eva Kottenberg; Matthias Thielmann; Heinz Jakob; Jürgen Peters
Journal:  Anesthesiology       Date:  2011-12       Impact factor: 7.892

10.  Aprotinin counteracts heparin-induced inhibition of platelet contractile force.

Authors:  Marcus E Carr; Sheryl L Carr; Veronica Roa; Kathleen A McCardell; Philip E Greilich
Journal:  Thromb Res       Date:  2002-11-01       Impact factor: 3.944

View more
  2 in total

Review 1.  Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing.

Authors:  Mohammad Mohammadi Aria; Ahmet Erten; Ozlem Yalcin
Journal:  Front Bioeng Biotechnol       Date:  2019-12-11

2.  Waterproof Flexible Polymer-Functionalized Graphene-Based Piezoresistive Strain Sensor for Structural Health Monitoring and Wearable Devices.

Authors:  Vetrivel Sankar; Ashwin Nambi; Vivek Nagendra Bhat; Debadatta Sethy; Krishnan Balasubramaniam; Sumitesh Das; Mriganshu Guha; Ramaprabhu Sundara
Journal:  ACS Omega       Date:  2020-05-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.