Literature DB >> 29482977

Transcatheter Mitral Valve Repair Using the Edge-to-Edge Clip.

Charles B Nyman1, G Burkhard Mackensen2, Srdjan Jelacic2, Stephen H Little3, Thomas W Smith4, Feroze Mahmood5.   

Abstract

Percutaneous intervention for mitral valve (MV) disease has been established as an alternative to open surgical MV repair in patients with prohibitive surgical risk. Multiple percutaneous approaches have been described and are in various stages of development. Edge-to-edge leaflet plication with the MitraClip (Abbott, Menlo Park, CA) is currently the only Food and Drug Administration-approved device specifically for primary or degenerative lesions. Use of the edge-to-edge clip for secondary mitral regurgitation is currently under investigation and may result in expanded indications. Echocardiography has significantly increased our understanding of the anatomy of the MV and provided us with the ability to classify and quantify the associated mitral regurgitation. For percutaneous interventions of the MV, transesophageal echocardiography imaging is used for patient screening, intraprocedural guidance, and confirmation of the result. Optimal outcomes require the echocardiographer and the proceduralist to have a thorough understanding of intra-atrial septal and MV anatomy, as well as an appreciation for the key points and potential pitfalls of each of the procedural steps. With increasing experience, more complex valvular pathology can be successfully percutaneously treated. In addition to two-dimensional echocardiography, advances in three-dimensional echocardiography and fusion imaging will continue to support the refinement of current technologies, the expansion of clinical applications, and the development of novel devices.
Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D echocardiography; Interventional echocardiography; MitraClip; Percutaneous mitral valve repair

Mesh:

Year:  2018        PMID: 29482977     DOI: 10.1016/j.echo.2018.01.012

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

Review 1.  Echocardiographic guidance for transcatheter mitral valve repair using edge-to-edge clip.

Authors:  Edris Aman; Thomas W Smith
Journal:  J Echocardiogr       Date:  2019-02-15

2.  Outcomes after Transcatheter Mitral Valve Edge to Edge Repair; a Comparison of Two Pathologies.

Authors:  Haytham El-Shurafa; Monirah Albabtain; Amr Arafat; Weam Abdulsalam; Juan Alfonso; Khalifa Ashmeik; Aijaz Shah; Mohammad AlOtaiby
Journal:  Acta Cardiol Sin       Date:  2021-05       Impact factor: 2.672

Review 3.  Real-Time Monitoring and Step-by-Step Guidance for Transapical Mitral Valve Edge-to-Edge Repair Using Transesophageal Echocardiography.

Authors:  Zhenyi Ge; Cuizhen Pan; Wei Li; Daxin Zhou; Wenzhi Pan; Lai Wei; Haiyan Chen; Xianhong Shu; Junbo Ge
Journal:  J Interv Cardiol       Date:  2021-04-21       Impact factor: 2.279

4.  Comparison of clinical and echocardiographic outcomes and quality of life in patients with severe mitral regurgitation treated by MitraClip implantation or treated conservatively.

Authors:  Agata Krawczyk-Ożóg; Zbigniew Siudak; Danuta Sorysz; Mateusz K Hołda; Anna Płotek; Artur Dziewierz; Andrzej Gackowski; Dariusz Dudek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-09-21       Impact factor: 1.426