Literature DB >> 29479390

Acute Stent Loss and Its Retrieval of a Long, Tapering Morph Stent in a Tortuous, Calcified Lesion.

Santosh Kumar Sinha1, Anupam Mahrotra1, Nishant Kumar Abhishekh1, Mahmodula Razi1, Puneet Aggarwal1, Sunil Tripathi1, Lokendra Rekwaal1, Anupam Singh1.   

Abstract

A 72-year-old male with diabetes and smoking as coronary risk factors was evaluated for chronic stable angina - Canadian Cardiovascular Society III - despite guideline directed medical treatment which revealed a diffuse, tortuous, calcified narrowing (90% stenosis) in left circumflex (LCx) coronary artery. After predilatation, a 3.0 - 2.5 × 60 mm BioMime Morph stent - long tapering stent (Sirolimus eluting stent, Meril life Sciences, India) - was tracked which failed and dislodged to right deep femoral artery during its pullback. It was successfully retrieved by EN snare: 6 - 10 mm (Merit Medical, USA) by contralateral femoral approach. Lesion was further dilated and successfully stented with another 3.0 - 2.5 × 60 mm BioMime Morph stent at 10 atm pressure showing proper stents expansion with TIMI-3 coronary flow. Our case highlights trackibility issues and importance of adequate lesion preparation before stent deployment in a tortuous and calcified vessel especially with very long stent. To the best of our knowledge, this is the first such case report demonstrating dislodgement and successful retrieval of long, tapered Morph stent.

Entities:  

Keywords:  Calcium; Chronic stable angina; EN snare; Morph stent; Stent dislodgement; Tapered stent

Year:  2018        PMID: 29479390      PMCID: PMC5819633          DOI: 10.14740/cr627w

Source DB:  PubMed          Journal:  Cardiol Res        ISSN: 1923-2829


  9 in total

1.  Incidence, management, and outcome of stent loss during intracoronary stenting.

Authors:  J Bolte; U Neumann; C Pfafferott; A Vogt; H J Engel; H C Mehmel; K E von Olshausen
Journal:  Am J Cardiol       Date:  2001-09-01       Impact factor: 2.778

2.  Stent Complications.

Authors: 
Journal:  J Invasive Cardiol       Date:  1998-09       Impact factor: 2.022

3.  Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation.

Authors:  Lorenz Räber; Peter Jüni; Lukas Löffel; Simon Wandel; Stéphane Cook; Peter Wenaweser; Mario Togni; Rolf Vogel; Christian Seiler; Franz Eberli; Thomas Lüscher; Bernhard Meier; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2010-03-23       Impact factor: 24.094

4.  Embolised stent into the circumflex coronary artery during percutaneous coronary intervention.

Authors:  Cihangir Uyan; Hüseyin Gündüz; Hüseyin Arinc; Ramazan Akdemir
Journal:  Int Heart J       Date:  2006-01       Impact factor: 1.862

5.  Transradial retrieval of a dislodged stent from the left main coronary artery.

Authors:  Walid Ahmar; Yuvaraj Malaiapan; Ian T Meredith
Journal:  J Invasive Cardiol       Date:  2008-10       Impact factor: 2.022

6.  Nonsurgical retrieval of embolized coronary stents.

Authors:  H Eggebrecht; M Haude; C von Birgelen; O Oldenburg; D Baumgart; J Herrmann; D Welge; T Bartel; N Dagres; R Erbel
Journal:  Catheter Cardiovasc Interv       Date:  2000-12       Impact factor: 2.692

7.  Incidence, retrieval methods, and outcomes of stent loss during percutaneous coronary intervention: a large single-center experience.

Authors:  Emmanouil S Brilakis; Patricia J M Best; Ahmad A Elesber; Gregory W Barsness; Ryan J Lennon; David R Holmes; Charanjit S Rihal; Kirk N Garratt
Journal:  Catheter Cardiovasc Interv       Date:  2005-11       Impact factor: 2.692

8.  [Coronary artery lumen diameter and bifurcation angle derived from CT coronary angiographic image in healthy people].

Authors:  Li-ren Zhang; Dong-sheng Xu; Xiao-cheng Liu; Xue-sheng Wu; Yuan-ning Ying; Zhi Dong; Feng-wei Sun; Pi-pi Yang; Xu Li
Journal:  Zhonghua Xin Xue Guan Bing Za Zhi       Date:  2011-12

9.  Mechanical modeling of stents deployed in tapered arteries.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  Ann Biomed Eng       Date:  2008-10-10       Impact factor: 3.934

  9 in total
  3 in total

1.  Left main stenting with stent dislodgement and entrapment in the common femoral artery: a successful transcatheter stent retrieval.

Authors:  Obiora Egbuche; Kenechukwu N Mezue; Shirley I Nwokike; Temidayo Abe; Titilope Olanipekun; Ifeoma Onuorah; Carter Tharpe
Journal:  Am J Cardiovasc Dis       Date:  2021-06-15

2.  Real-World Experience With a Tapered Biodegradable Polymer-Coated Sirolimus-Eluting Stent in Patients With Long Coronary Artery Stenoses.

Authors:  Alessandro Lupi; Fabrizio Ugo; Leonardo De Martino; Vincenzo Infantino; Mario Iannaccone; Sergio Iorio; Angelo Di Leo; Salvatore Colangelo; Marco Zanera; Alon Schaffer; Simone Persampieri; Roberto Garbo; Gaetano Senatore
Journal:  Cardiol Res       Date:  2020-06-03

3.  Clinical Outcomes of Novel Long-Tapered Sirolimus-Eluting Coronary Stent System in Real-World Patients With Long Diffused De Novo Coronary Lesions.

Authors:  Suresh V Patted; Rajendra Kumar Jain; P A Jiwani; Satish Suryavanshi; T R Raghu; Hema Raveesh; S Rajalakshmi; Ashok S Thakkar; Prakash Kumar Turiya; Priyanka J Desai; Anmol Suresh Patted; Kamal H Sharma
Journal:  Cardiol Res       Date:  2018-12-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.