Literature DB >> 29477564

Comparison of laboratory and ambulatory measures of central blood pressure and pulse wave reflection: hitting the target or missing the mark?

Matthew J Burns1, Jeremy D Seed1, Anthony V Incognito1, Connor J Doherty1, Karambir Notay1, Philip J Millar2.   

Abstract

Prior studies demonstrating clinical significance of noninvasive estimates of central blood pressure (BP) and pulse wave reflection have relied primarily on discrete resting measures. The aim of this study was to compare central BP and pulse wave reflection measures sampled during a single resting laboratory visit against those obtained under ambulatory conditions. The secondary aim was to investigate the reproducibility of ambulatory central BP and pulse wave reflection measurements. Forty healthy participants (21 males; 24 ± 3 years) completed three measurements of brachial artery pulse wave analysis (Oscar 2 with SphygmoCor Inside) in the laboratory followed by 24 hours of ambulatory monitoring. Seventeen participants repeated the 24-hour ambulatory monitoring visit after at least 1 week. Ambulatory measures were divided into daytime (9 AM-9 PM), nighttime (1 AM-6 AM), and 24-hour periods. Compared with laboratory measurements, central systolic BP, augmentation pressure, and augmentation index (with and without heart rate normalization) were higher (all P < .01) during daytime and 24-hour periods but lower during the nighttime period (all P < .001). The drop in nighttime brachial systolic BP was larger than central systolic pressure (Δ -20 ± 6 vs. -15 ± 6 mm Hg; P < .0001). Repeat ambulatory measurements of central BP and pulse wave reflection displayed good-to-excellent intraclass correlation coefficients (r = 0.58-0.86; all P < .01), although measures of pulse wave reflection had higher coefficients of variation (14%-41%). The results highlight absolute differences in central BP and pulse wave reflection between discrete laboratory and ambulatory conditions. The use of ambulatory measures of central BP and pulse wave reflection warrant further investigation for clinical prognostic value.
Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ambulatory blood pressure; augmentation pressure; central blood pressure; pulse wave reflection

Year:  2018        PMID: 29477564     DOI: 10.1016/j.jash.2018.01.014

Source DB:  PubMed          Journal:  J Am Soc Hypertens        ISSN: 1878-7436


  3 in total

1.  Ambulatory blood pressure and arterial stiffness web-based telemonitoring in patients at cardiovascular risk. First results of the VASOTENS (Vascular health ASsessment Of The hypertENSive patients) Registry.

Authors:  Stefano Omboni; Igor Posokhov; Gianfranco Parati; Anatoly Rogoza; Yulia Kotovskaya; Ayana Arystan; Alberto Avolio; Vitaliy Barkan; Natalia Bulanova; Ernesto Cardona Muñoz; Elena Grigoricheva; Alexandra Konradi; Irina Minyukhina; Maria Lorenza Muiesan; Giuseppe Mulè; Iana Orlova; Telmo Pereira; João Manuel Peixoto Maldonado; Mikhail E Statsenko; Ioan Tilea; Gabriel Waisman
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-07-11       Impact factor: 3.738

2.  Diurnal changes in central blood pressure and pulse pressure amplification in patients with obstructive sleep apnoea.

Authors:  Yasmina Serinel; Camilla Hoyos; Ahmad Qasem; Brendon J Yee; Ronald R Grunstein; Keith H Wong; Craig L Phillips
Journal:  Int J Cardiol Hypertens       Date:  2019-04-09

3.  Twenty-Four-Hour Central (Aortic) Systolic Blood Pressure: Reference Values and Dipping Patterns in Untreated Individuals.

Authors:  Thomas Weber; Athanase D Protogerou; Mohsen Agharazii; Antonis Argyris; Sola Aoun Bahous; Jose R Banegas; Ronald K Binder; Jacques Blacher; Andréa Araujo Brandao; Juan J Cruz; Kathrin Danninger; Cristina Giannatasio; Auxiliadora Graciani; Bernhard Hametner; Piotr Jankowski; Yan Li; Alessandro Maloberti; Christopher C Mayer; Barry J McDonnell; Carmel M McEniery; Marco Antonio Mota Gomes; Annelise Machado Gomes; Maria Lorenza Muiesan; Janos Nemcsik; Anna Paini; Enrique Rodilla; Aletta E Schutte; Petros P Sfikakis; Dimitrios Terentes-Printzios; Alexandre Vallée; Charalambos Vlachopoulos; Lisa Ware; Ian Wilkinson; Robert Zweiker; James E Sharman; Siegfried Wassertheurer
Journal:  Hypertension       Date:  2021-11-15       Impact factor: 10.190

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.