Literature DB >> 29472113

Revised Value of Contrast-Enhanced Ultrasound for Solid Hypo-Echoic Thyroid Nodules Graded with the Thyroid Imaging Reporting and Data System.

YanFang Wang1, Fang Nie2, Ting Liu1, Dan Yang1, Qi Li1, Jing Li1, AiLing Song3.   

Abstract

The use of ultrasound in differentiation of benign and malignant solid hypo-echoic thyroid nodules is a dilemma in clinical practice. The aim of this study was to investigate the revised value of contrast-enhanced ultrasound (CEUS) for differentiating solid hypo-echoic thyroid nodules using the Thyroid Imaging Reporting and Data System (TI-RADS).The study included 135 patients with 135 nodules confirmed by fine-needle aspiration and/or surgery. Every nodule underwent both conventional US and CEUS. Binary logistic regression analysis for conventional US features revealed that irregular shape, microcalcification and height greater than width were significant malignant predictive features. Binary logistic analysis for CEUS features indicated that hetero-enhancement, slow wash-in, an ill-defined enhancement border and fast wash-out were significantly associated with malignancy. The areas under the curve of the TI-RADS, CEUS and the combination were 0.806, 0.934 and 0.950, respectively. CEUS is a potentially useful tool in the differentiation of solid hypo-echoic thyroid nodules.
Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contrast-enhanced ultrasound; Solid hypo-echoic thyroid nodules; Thyroid Imaging Reporting and Data System

Mesh:

Substances:

Year:  2018        PMID: 29472113     DOI: 10.1016/j.ultrasmedbio.2017.12.018

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Taller-than-wide Thyroid Nodules With Microcalcifications Are at High Risk of Malignancy.

Authors:  Konstantinos D Papapostolou; Catherine C Evangelopoulou; Ioannis A Ioannidis; Georgia N Kassi; Konstantinos S Morfas; Nikolaos I Karaminas; Helen J Karga
Journal:  In Vivo       Date:  2020 Jul-Aug       Impact factor: 2.155

2.  Combination of contrast-enhanced ultrasound and strain elastography to assess cytologically non-diagnostic thyroid nodules.

Authors:  Zi-Mei Lin; Qing Wen; Cao-Xin Yan; Min-Qiang Pan; Guo-Qiang Mo; Ji-Fan Chen; Pin-Tong Huang
Journal:  Oncol Lett       Date:  2019-11-05       Impact factor: 2.967

3.  Qualitative analysis of contrast-enhanced ultrasound in the diagnosis of small, TR3-5 benign and malignant thyroid nodules measuring ≤1 cm.

Authors:  Xin Li; Feng Gao; Fan Li; Xiao-Xia Han; Si-Hui Shao; Ming-Hua Yao; Chun-Xiao Li; Jun Zheng; Rong Wu; Lian-Fang Du
Journal:  Br J Radiol       Date:  2020-04-09       Impact factor: 3.039

4.  Contrast-enhanced ultrasound for the differential diagnosis of thyroid nodules: An updated meta-analysis with comprehensive heterogeneity analysis.

Authors:  Juanjuan Zhang; Xiuting Zhang; Yanna Meng; Yinghong Chen
Journal:  PLoS One       Date:  2020-04-20       Impact factor: 3.240

5.  Benefits of Contrast-Enhanced Ultrasonography to the Differential Diagnosis of TI-RADS 4-5 Thyroid Nodules.

Authors:  Ping Yu; Sihua Niu; Shuang Gao; Hui Tian; Jiaan Zhu
Journal:  Appl Bionics Biomech       Date:  2022-04-15       Impact factor: 1.781

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.