Literature DB >> 29469676

The Glittre-ADL Test Cut-Off Point to Discriminate Abnormal Functional Capacity in Patients with COPD.

Aline Almeida Gulart1,2, Anelise Bauer Munari1,2, Suelen Roberta Klein1,2, Lucas Santos da Silveira1,3, Anamaria Fleig Mayer1,2,3.   

Abstract

The study objective was to determine a cut-off point for the Glittre activities of daily living (ADL)test (TGlittre) to discriminate patients with normal and abnormal functional capacity. Fifty-nine patients with moderate to very severe COPD (45 males; 65 ± 8.84 years; BMI: 26 ± 4.78 kg/m2; FEV1: 35.3 ± 13.4% pred) were evaluated for spirometry, TGlittre, 6-minute walk test (6 MWT), physical ADL, modified Medical Research Council scale (mMRC), BODE index, Saint George's Respiratory Questionnaire (SGRQ), and COPD Assessment Test (CAT). The receiver operating characteristic (ROC) curve was used to determine the cut-off point for TGlittre in order to discriminate patients with 6 MWT < 82% pred. The ROC curve indicated a cut-off point of 3.5 minutes for the TGlittre (sensitivity = 92%, specificity = 83%, and area under the ROC curve = 0.95 [95% CI: 0.89-0.99]). Patients with abnormal functional capacity had higher mMRC (median difference 1 point), CAT (mean difference: 4.5 points), SGRQ (mean difference: 12.1 points), and BODE (1.37 points) scores, longer time of physical activity <1.5 metabolic equivalent of task (mean difference: 47.9 minutes) and in sitting position (mean difference: 59.4 minutes) and smaller number of steps (mean difference: 1,549 minutes); p < 0.05 for all. In conclusion, the cut-off point of 3.5 minutes in the TGlittre is sensitive and specific to distinguish COPD patients with abnormal and normal functional capacity.

Entities:  

Keywords:  Activities of daily living; functional capacity; outcome assessment (health care); outcome evaluation

Mesh:

Year:  2018        PMID: 29469676     DOI: 10.1080/15412555.2017.1369505

Source DB:  PubMed          Journal:  COPD        ISSN: 1541-2563            Impact factor:   2.409


  3 in total

1.  Respiratory Oscillometry in Chronic Obstructive Pulmonary Disease: Association with Functional Capacity as Evaluated by Adl Glittre Test and Hand Grip Strength Test.

Authors:  Caroline Oliveira Ribeiro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2022-05-04

Review 2.  Quantifying the Effect of Monitor Wear Time and Monitor Type on the Estimate of Sedentary Time in People with COPD: Systematic Review and Meta-Analysis.

Authors:  Fiona Coll; Vinicius Cavalheri; Daniel F Gucciardi; Sheldon Wulff; Kylie Hill
Journal:  J Clin Med       Date:  2022-04-01       Impact factor: 4.241

3.  From Inception to Implementation: Strategies for Setting Up Pulmonary Telerehabilitation.

Authors:  Catarina Duarte Santos; Fátima Rodrigues; Cátia Caneiras; Cristina Bárbara
Journal:  Front Rehabil Sci       Date:  2022-05-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.