Literature DB >> 29466277

Optimizing a Treadmill Ramp Protocol to Evaluate Aerobic Capacity of Hemiparetic Poststroke Patients.

Wendell L Bernardes1, Rafael A Montenegro2,3, Walace D Monteiro1,2, Raul de Almeida Freire2, Renato Massaferri2,3, Paulo Farinatti1,2.   

Abstract

Bernardes, WL, Montenegro, RA, Monteiro, WD, de Almeida Freire, R, Massaferri, R, and Farinatti, P. Optimizing a treadmill ramp protocol to evaluate aerobic capacity of hemiparetic poststroke patients. J Strength Cond Res 32(3): 876-884, 2018-A correct assessment of cardiopulmonary capacity is important for aerobic training within motor rehabilitation of poststroke hemiparetic patients (PSHPs). However, specific cardiopulmonary exercise testing (CPET) for these patients are scarce. We proposed adaptations in a protocol originally developed for PSHPs by Ovando et al. (CPET1). We hypothesized that our adapted protocol (CPET2) would improve the original test, by preventing early fatigue and increasing patients' peak performance. Eleven PSHPs (52 ± 14 years, 10 men) performed both protocols. CPET2 integrated changes in final speed (100-120% vs. 140% maximal speed in 10-m walking test), treadmill inclination (final inclination of 5 vs. 10%), and estimated test duration (10 vs. 8 minutes) to smooth the rate of workload increment of CPET1. Peak oxygen uptake (V[Combining Dot Above]O2peak) (20.3 ± 6.1 vs. 18.6 ± 5.0 ml·kg·min; p = 0.04), V[Combining Dot Above]O2 at gas exchange transition (V[Combining Dot Above]O2-GET) (11.5 ± 2.9 vs. 9.8 ± 2.0 ml·kg·min; p = 0.04), and time to exhaustion (10 ± 3 vs. 6 ± 2 minutes; p < 0.001) were higher in CPET2 than in CPET1. Slopes and intercepts of regressions describing relationships between V[Combining Dot Above]O2 vs. workload, heart rate vs. workload, and V[Combining Dot Above]O2 vs. heart rate were similar between CPETs. However, standard errors of estimates obtained for regressions between heart rate vs. workload (3.0 ± 1.3 vs. 3.8 ± 1.0 b·min; p = 0.004) and V[Combining Dot Above]O2 vs. heart rate (6.0 ± 2.1 vs. 4.8 ± 2.4 ml·kg·min; p = 0.05) were lower in CPET2 than in CPET1. In conclusion, the present adaptations in Ovando's CPET protocol increased exercise tolerance of PSHPs, eliciting higher V[Combining Dot Above]O2peak and V[Combining Dot Above]O2-GET, preventing earlier fatigue, and providing better physiological relationships along submaximal workloads.

Entities:  

Mesh:

Year:  2018        PMID: 29466277     DOI: 10.1519/JSC.0000000000002297

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  1 in total

1.  Mixed circuit training acutely reduces arterial stiffness in patients with chronic stroke: a crossover randomized controlled trial.

Authors:  André C Michalski; Arthur S Ferreira; Adrian W Midgley; Victor A B Costa; Guilherme F Fonseca; Nádia S L da Silva; Juliana Borges; Sandra A Billinger; Felipe A Cunha
Journal:  Eur J Appl Physiol       Date:  2022-10-07       Impact factor: 3.346

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.