Qi Huang1,2, Yunshuang Chen1, Min Zhang1, Sihe Wang3, Weiguang Zhang1, Guangyan Cai1, Xiangmei Chen1, Xuefeng Sun4. 1. Department of Nephrology, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, State Key Laboratory of Kidney Diseases, National Clinical Research Center for Kidney Diseases, 28 Fuxing Road, Beijing, 100853, China. 2. Department of Nephrology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China. 3. Department of Clinical Pathology, Cleveland Clinic, Cleveland, OH, USA. 4. Department of Nephrology, Chinese PLA General Hospital, Chinese PLA Institute of Nephrology, State Key Laboratory of Kidney Diseases, National Clinical Research Center for Kidney Diseases, 28 Fuxing Road, Beijing, 100853, China. xfssun@126.com.
Abstract
PURPOSE: We compared the performance of technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) renal dynamic imaging (RDI), the MDRD equation, and the CKD EPI equation to estimate glomerular filtration rate (GFR). METHODS: A total of 551 subjects, including CKD patients and healthy individuals, were enrolled in this study. Dual plasma sample clearance method of 99mTc-DTPA was used as the true value for GFR (tGFR). RDI and the MDRD and CKD EPI equations for estimating GFR were compared and evaluated. RESULTS: Data indicate that RDI and the MDRD equation underestimated GFR and CKD EPI overestimated GFR. RDI was associated with significantly higher bias than the MDRD and CKD EPI equations. The regression coefficient, diagnostic precision, and consistency of RDI were significantly lower than either equation. RDI and the MDRD equation underestimated GFR to a greater degree in subjects with tGFR ≥ 90 ml/min/1.73 m2 compared with the results obtained from all subjects. In the tGFR60-89 ml/min/1.73 m2 group, the precision of RDI was significantly lower than that of both equations. In the tGFR30-59 ml/min/1.73 m2 group, RDI had the least bias, the most precision, and significantly higher accuracy compared with either equation. In tGFR < 30 ml/min/1.73 m2, the three methods had similar performance and were not significantly different. CONCLUSIONS: RDI significantly underestimates GFR and performs no better than MDRD and CKD EPI equations for GFR estimation; thus, it should not be recommended as a reference standard against which other GFR measurement methods are assessed. However, RDI better estimates GFR than either equation for individuals in the tGFR30-59 ml/min/1.73 m2 group and thus may be helpful to distinguish stage 3a and 3b CKD.
PURPOSE: We compared the performance of technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) renal dynamic imaging (RDI), the MDRD equation, and the CKD EPI equation to estimate glomerular filtration rate (GFR). METHODS: A total of 551 subjects, including CKD patients and healthy individuals, were enrolled in this study. Dual plasma sample clearance method of 99mTc-DTPA was used as the true value for GFR (tGFR). RDI and the MDRD and CKD EPI equations for estimating GFR were compared and evaluated. RESULTS: Data indicate that RDI and the MDRD equation underestimated GFR and CKD EPI overestimated GFR. RDI was associated with significantly higher bias than the MDRD and CKD EPI equations. The regression coefficient, diagnostic precision, and consistency of RDI were significantly lower than either equation. RDI and the MDRD equation underestimated GFR to a greater degree in subjects with tGFR ≥ 90 ml/min/1.73 m2 compared with the results obtained from all subjects. In the tGFR60-89 ml/min/1.73 m2 group, the precision of RDI was significantly lower than that of both equations. In the tGFR30-59 ml/min/1.73 m2 group, RDI had the least bias, the most precision, and significantly higher accuracy compared with either equation. In tGFR < 30 ml/min/1.73 m2, the three methods had similar performance and were not significantly different. CONCLUSIONS: RDI significantly underestimates GFR and performs no better than MDRD and CKD EPI equations for GFR estimation; thus, it should not be recommended as a reference standard against which other GFR measurement methods are assessed. However, RDI better estimates GFR than either equation for individuals in the tGFR30-59 ml/min/1.73 m2 group and thus may be helpful to distinguish stage 3a and 3b CKD.
Authors: M D Blaufox; M Aurell; B Bubeck; E Fommei; A Piepsz; C Russell; A Taylor; H S Thomsen; D Volterrani Journal: J Nucl Med Date: 1996-11 Impact factor: 10.057
Authors: N G De Santo; P Anastasio; M Cirillo; D Santoro; L Spitali; L Mansi; L Celentano; D Capodicasa; E Cirillo; E Del Vecchio; C Pascale; G Capasso Journal: Nephron Date: 1999-02 Impact factor: 2.847
Authors: J J Goates; K A Morton; W W Whooten; H E Greenberg; F L Datz; J E Handy; A J Scuderi; A O Haakenstad; R E Lynch Journal: J Nucl Med Date: 1990-04 Impact factor: 10.057
Authors: B Frennby; T Almén; B Lilja; L G Eriksson; S Hellsten; B Lindblad; M Nilsson; U Nyman; C Törnquist Journal: Acta Radiol Date: 1995-07 Impact factor: 1.990
Authors: Brian R Lane; Sevag Demirjian; Christopher J Weight; Benjamin T Larson; Emilio D Poggio; Steven C Campbell Journal: J Urol Date: 2010-01-18 Impact factor: 7.450