Literature DB >> 29464341

Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: a pilot study of extra-pulmonary vein ablation.

Shinsuke Miyazaki1,2, Takatsugu Kajiyama3, Tomonori Watanabe3, Sadamitsu Ichijo3, Yoshito Iesaka3.   

Abstract

Isolation areas post-28-mm cryoballoon pulmonary vein isolation (CB-PVI) are smaller than post-radiofrequency PV antrum isolation at the left superior PV (LSPV) antrum and recurrent atrial fibrillation (AF) can originate from this area. This pilot study evaluated the impact of additional extra-PV CB applications at the LSPV antrum following conventional CB-PVI. Eighteen paroxysmal AF patients underwent CB-PVI with single 3-min freeze techniques. Following the CB-PVI, 2-min CB applications were added once or twice at the LSPV antrum. Before and after extra-PV ablation, left atrial (LA) 3-D electroanatomical maps were created. Seventy-two total PVs were successfully isolated with 4.2 ± 0.4 applications/patient with 28-mm CBs. The mean LA posterior wall (LAPW) and non-isolated LAPW areas were 14.9 ± 3.6 and 6.9 ± 2.8 cm2, respectively. After 1.6 ± 0.5 mean extra-PV applications, the upper non-isolated LAPW area significantly decreased from 3.3 ± 1.8 to 2.5 ± 1.8 cm2 (p < 0.001). The lowest esophageal temperatures during the extra-PV ablation were 27 °C. The total procedure and fluoroscopic times were 72.8 ± 13.1 and 15.2 ± 5.9 min, respectively. Silent gastric hypomotility was detected in 2/9 patients 1 day later, and mild PV stenosis was observed in 4/72 PVs 3 months later, but did not progress. At 12-month after single procedures, 16 (88.9%) patients were free from recurrent AF off antiarrhythmic drugs. A median of 8.0 [6.0-10.0] months later, PV reconnections were detected in 3/12 (25.0%) PVs. The non-isolated LAPW area was significantly larger in the chronic than acute phase (14.3 ± 5.2 cm2, p = 0.016). This pilot study suggested the potential feasibility of additional LSPV antral cryoapplications following a conventional CB-PVI. The strategy warrants further study in more patients.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Cryoballoon; Pulmonary vein isolation

Mesh:

Year:  2018        PMID: 29464341     DOI: 10.1007/s00380-018-1142-4

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  27 in total

1.  Clinical recurrence and electrical pulmonary vein reconnections after second-generation cryoballoon ablation.

Authors:  Shinsuke Miyazaki; Hiroshi Taniguchi; Hitoshi Hachiya; Hiroaki Nakamura; Takamitsu Takagi; Kenzo Hirao; Yoshito Iesaka
Journal:  Heart Rhythm       Date:  2016-05-27       Impact factor: 6.343

2.  Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation.

Authors:  Raphaël P Martins; David Hamon; Olivier Césari; Albin Behaghel; Nathalie Behar; Jean-Marc Sellal; Jean-Claude Daubert; Philippe Mabo; Dominique Pavin
Journal:  Heart Rhythm       Date:  2014-01-01       Impact factor: 6.343

3.  Prediction of the critical thermal zone during pulmonary cryoablation on computed tomography from correlated experimental and clinical findings.

Authors:  Kohei Hashimoto; Yotaro Izumi; Yoshikane Yamauchi; Hideki Yashiro; Masanori Inoue; Seishi Nakatsuka; Hiroaki Nomori
Journal:  J Thorac Cardiovasc Surg       Date:  2012-04-13       Impact factor: 5.209

4.  Pulmonary Vein Isolation Using a Second-Generation Cryoballoon in Patients With Paroxysmal Atrial Fibrillation: One-Year Outcome Using a Single Big-Balloon 3-Minute Freeze Technique.

Authors:  Shinsuke Miyazaki; Hitoshi Hachiya; Hiroaki Nakamura; Hiroshi Taniguchi; Takamitsu Takagi; Kenzo Hirao; Yoshito Iesaka
Journal:  J Cardiovasc Electrophysiol       Date:  2016-09-14

5.  Achievement of pulmonary vein isolation in patients undergoing circumferential pulmonary vein ablation: a randomized comparison between two different isolation approaches.

Authors:  Xingpeng Liu; Jianzeng Dong; Hercules E Mavrakis; Fuli Hu; Deyong Long; Dongping Fang; Ronghui Yu; Ribo Tang; Peng Hao; Chunshan Lu; Xiaokui He; Xiaohui Liu; Panos E Vardas; Changsheng Ma
Journal:  J Cardiovasc Electrophysiol       Date:  2006-12

6.  Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study.

Authors:  Vivek Y Reddy; Lucie Sediva; Jan Petru; Jan Skoda; Milan Chovanec; Zita Chitovova; Paola Di Stefano; Ethel Rubin; Srinivas Dukkipati; Petr Neuzil
Journal:  J Cardiovasc Electrophysiol       Date:  2015-04-15

7.  Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation.

Authors:  Pipin Kojodjojo; Mark D O'Neill; Phang Boon Lim; Louisa Malcolm-Lawes; Zachary I Whinnett; Tushar V Salukhe; Nicholas W Linton; David Lefroy; Anthony Mason; Ian Wright; Nicholas S Peters; Prapa Kanagaratnam; D Wyn Davies
Journal:  Heart       Date:  2010-09       Impact factor: 5.994

8.  Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study.

Authors:  Thomas Arentz; Reinhold Weber; Gerd Bürkle; Claudia Herrera; Thomas Blum; Jochem Stockinger; Jan Minners; Franz Josef Neumann; Dietrich Kalusche
Journal:  Circulation       Date:  2007-06-11       Impact factor: 29.690

9.  Quantitative Analysis of the Isolation Area During the Chronic Phase After a 28-mm Second-Generation Cryoballoon Ablation Demarcated by High-Resolution Electroanatomic Mapping.

Authors:  Shinsuke Miyazaki; Hiroshi Taniguchi; Hitoshi Hachiya; Hiroaki Nakamura; Takamitsu Takagi; Jin Iwasawa; Kenzo Hirao; Yoshito Iesaka
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-05

10.  Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation.

Authors:  Karl-Heinz Kuck; Josep Brugada; Alexander Fürnkranz; Andreas Metzner; Feifan Ouyang; K R Julian Chun; Arif Elvan; Thomas Arentz; Kurt Bestehorn; Stuart J Pocock; Jean-Paul Albenque; Claudio Tondo
Journal:  N Engl J Med       Date:  2016-04-04       Impact factor: 91.245

View more
  1 in total

1.  Incidence of Long-Term Pulmonary Vein Reconnection after a 2-Minute Cryoballoon Freeze for Pulmonary Vein Isolation-Invasive Insights of TTI-Dependent Cryoenergy Titration.

Authors:  Alexander Pott; Michael Baumhardt; Mohammad Al-Masalmeh; Alexander Wolf; Matthias Schiele; Christiane Schweizer; Carlo Bothner; Deniz Aktolga; Yannick Teumer; Karolina Weinmann; Wolfgang Rottbauer; Tillman Dahme
Journal:  J Cardiovasc Dev Dis       Date:  2022-08-23
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.