Literature DB >> 29463157

Comparing Recalibration Strategies for Electroencephalography-Based Decoders of Movement Intention in Neurological Patients with Motor Disability.

Eduardo López-Larraz1,2, Jaime Ibáñez3,4, Fernando Trincado-Alonso5, Esther Monge-Pereira6, José Luis Pons4,7, Luis Montesano2,8.   

Abstract

Motor rehabilitation based on the association of electroencephalographic (EEG) activity and proprioceptive feedback has been demonstrated as a feasible therapy for patients with paralysis. To promote long-lasting motor recovery, these interventions have to be carried out across several weeks or even months. The success of these therapies partly relies on the performance of the system decoding movement intentions, which normally has to be recalibrated to deal with the nonstationarities of the cortical activity. Minimizing the recalibration times is important to reduce the setup preparation and maximize the effective therapy time. To date, a systematic analysis of the effect of recalibration strategies in EEG-driven interfaces for motor rehabilitation has not yet been performed. Data from patients with stroke (4 patients, 8 sessions) and spinal cord injury (SCI) (4 patients, 5 sessions) undergoing two different paradigms (self-paced and cue-guided, respectively) are used to study the performance of the EEG-based classification of motor intentions. Four calibration schemes are compared, considering different combinations of training datasets from previous and/or the validated session. The results show significant differences in classifier performances in terms of the true and false positives (TPs) and (FPs). Combining training data from previous sessions with data from the validation session provides the best compromise between the amount of data needed for calibration and the classifier performance. With this scheme, the average true (false) positive rates obtained are 85.3% (17.3%) and 72.9% (30.3%) for the self-paced and the cue-guided protocols, respectively. These results suggest that the use of optimal recalibration schemes for EEG-based classifiers of motor intentions leads to enhanced performances of these technologies, while not requiring long calibration phases prior to starting the intervention.

Entities:  

Keywords:  Brain–machine interfaces (BMI); movement intention; rehabilitation; spinal cord injury (SCI); stroke

Mesh:

Year:  2017        PMID: 29463157     DOI: 10.1142/S0129065717500605

Source DB:  PubMed          Journal:  Int J Neural Syst        ISSN: 0129-0657            Impact factor:   5.866


  2 in total

1.  Event-related desynchronization during movement attempt and execution in severely paralyzed stroke patients: An artifact removal relevance analysis.

Authors:  Eduardo López-Larraz; Thiago C Figueiredo; Ainhoa Insausti-Delgado; Ulf Ziemann; Niels Birbaumer; Ander Ramos-Murguialday
Journal:  Neuroimage Clin       Date:  2018-10-04       Impact factor: 4.881

2.  On the design of EEG-based movement decoders for completely paralyzed stroke patients.

Authors:  Martin Spüler; Eduardo López-Larraz; Ander Ramos-Murguialday
Journal:  J Neuroeng Rehabil       Date:  2018-11-20       Impact factor: 4.262

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.