| Literature DB >> 29461506 |
Shi-Chang Tseng1, Tong-Yu Wu2, Jung-Chuan Chou3,4, Yi-Hung Liao5, Chih-Hsien Lai6,7, Siao-Jie Yan8, Ting-Wei Tseng9.
Abstract
We investigate the temperature effect on sensing characteristics and drift effect of an arrayed flexible ruthenium dioxide (RuO₂)/graphene oxide (GO) chloride sensor at different solution temperatures between 10 °C and 50 °C. The average sensor sensitivities according to our experimental results were 28.2 ± 1.4 mV/pCl (10 °C), 42.5 ± 2.0 mV/pCl (20 °C), 47.1 ± 1.8 mV/pCl (30 °C), 54.1 ± 2.01 mV/pCl (40 °C) and 46.6 ± 2.1 mV/pCl (50 °C). We found the drift effects of an arrayed flexible RuO₂/GO chloride sensor in a 1 M NaCl solution to be between 8.2 mV/h and 2.5 mV/h with solution temperatures from 10 °C to 50 °C.Entities:
Keywords: chloride ion sensor; drift effect; graphene oxide; ruthenium dioxide; temperature effect
Year: 2018 PMID: 29461506 PMCID: PMC5855318 DOI: 10.3390/s18020632
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1The mercury organic ionophore structure (ETH9033) [10].
Figure 2The fabrication process of the arrayed flexible RuO2/GO chloride ion sensor [14,29,30].
Figure 3The schematic diagram of the arrayed flexible RuO2/GO chloride sensor [14].
Figure 4The schematic diagram of V-T measurement system with LT1167 instrumentation amplifier for the arrayed flexible RuO2/GO chloride sensor [30].
Figure 5The curve of the response potential versus different chloride concentrations for the arrayed flexible RuO2/GO chloride sensor from 10−5 M to 1 M NaCl solutions at room temperature 25 °C.
The comparisons of the average sensitivity of the arrayed flexible RuO2/GO chloride sensor and other research on different chloride concentrations.
| Sensing Film | Sensing Mechanism | Sensitivity (pCl) | Detection Chloride Range (M) | Reference |
|---|---|---|---|---|
| PET/RuO2/GO/chloride film | Potentiometric | 41.0 mV/pCl | 1 × 10−5 M to 1 M | In this study |
| PET/RuO2 chloride film | Potentiometric | 25.1 mV/pCl | 1 × 10−5 M to 1 M | [ |
| PET/AgCl paste | Potentiometric | 57.0 mV/decade | 1 × 10−3 M to 3 M | [ |
| Alumina/silver | Potentiometric | 59.2 mV/pCl | 6.25 × 10−4 M to 1 M | [ |
| Carbon paste electrode | Amperometric | 1.1 nA/µM | 1 × 10−4 M to 1 × 10−3 M | [ |
Figure 6The average sensitivities and linearities of the different temperatures for the arrayed flexible RuO2/GO chloride sensor.
Comparison of the sensitivities of PET/RuO2/GO and PET/RuO2 [37] chloride sensor at different solution temperatures.
| Solution Temperature (°C) | Sensitivity (mV/pCl) | |
|---|---|---|
| PET/RuO2/GO (In This Study) | PET/RuO2 [ | |
| 10 | 28.2 ± 1.4 | 27.7 ± 0.0 |
| 20 | 42.5 ± 2.0 | 36.8 ± 0.0 |
| 30 | 47.1 ± 1.8 | 39.8 ± 1.3 |
| 40 | 54.1 ± 2.0 | 41.5 ± 1.6 |
| 50 | 46.6 ± 2.1 | 22.6 ± 0.0 |
Figure 7The response potentials of the arrayed flexible RuO2/GO chloride sensor at different NaCl solution temperatures from 10 °C to 50 °C.
Figure 8The electrochemical impedances of fitted curves at the different chloride ion concentrations.
The fitted results of Ret, Rs and Cdl of the arrayed flexible RuO2/GO chloride sensor at different NaCl concentrations solution from 1 × 10−5 M to 1 M.
| NaCl Concentration (M) | Ret (kΩ) | Rs (kΩ) | Cdl (pF) |
|---|---|---|---|
| 1 | 584.3 ± 30.7 | 3.5 ± 0.1 | 73.4 ± 0.8 |
| 0.1 | 1047.3 ± 6.4 | 2.7 ± 0.2 | 93.8 ± 0.8 |
| 1 × 10−2 | 1131.7 ± 24.8 | 2.6 ± 0.3 | 88.8 ± 0.2 |
| 1 × 10−3 | 1681.0 ± 32.9 | 3.4 ± 0.3 | 85.8 ± 2.7 |
| 1 × 10−4 | 1728.3 ± 44.2 | 4.6 ± 0.3 | 70.4 ± 1.0 |
| 1 × 10−5 | 2350.5 ± 71.4 | 3.3 ± 0.3 | 94.0 ± 0.8 |
Figure 9The electrochemical impedances of fitted curves in the different solution temperatures from 10 °C to 50 °C.
The fitted results of Ret, Rs and Cdl in 1 M NaCl solution at the different solution temperatures.
| Solution Temperature | Electron Transfer Resistance | Solution Resistance | Double Layer Capacitor |
|---|---|---|---|
| 10 | 274.7 ± 52.7 | 0.4 ± 0.2 | 238 ± 37.6 |
| 20 | 129.9 ± 25.1 | 3.6 ± 1.8 | 535 ± 29.4 |
| 30 | 83.8 ± 4.3 | 2.5 ± 0.2 | 543 ± 21.0 |
| 40 | 41.5 ± 13.0 | 1.2 ± 1.3 | 339 ± 37.5 |
| 50 | 34.9 ± 11.8 | 2.1 ± 0.9 | 416 ± 10.2 |
The drift rates of the arrayed flexible RuO2/GO chloride sensor in the 1 M NaCl solution from 10 to 50 °C.
| Solution Temperature (°C) | Drift Rate (mV/h) |
|---|---|
| 10 | 8.2 |
| 20 | 4.7 |
| 30 | 4.2 |
| 40 | 3.6 |
| 50 | 2.5 |