Literature DB >> 29455281

Sensitive colorimetric assay for uric acid and glucose detection based on multilayer-modified paper with smartphone as signal readout.

Xu Wang1, Fang Li2, Ziqi Cai1, Kaifan Liu1, Jing Li1, Boyang Zhang1, Jianbo He1.   

Abstract

In this work, a multilayer-modified paper-based colorimetric sensing platform with improved color uniformity and intensity was developed for the sensitive and selective determination of uric acid and glucose with smartphone as signal readout. In detail, chitosan, different kinds of chromogenic reagents, and horseradish peroxidase (HRP) combined with a specific oxidase, e.g., uricase or glucose oxidase (GOD), were immoblized onto the paper substrate to form a multilayer-modified test paper. Hydrogen peroxide produced by the oxidases (uricase or GOD) reacts with the substrates (uric acid or glucose), and could oxidize the co-immoblized chromogenic reagents to form colored products with HRP as catalyst. A simple strategy by placing the test paper on top of a light-emitting diode lamp was adopted to efficiently prevent influence from the external light. The color images were recorded by the smartphone camera, and then the gray values of the color images were calculated for quantitative analysis. The developed method provided a wide linear response from 0.01 to 1.0 mM for uric acid detection and from 0.02 to 4.0 mM for glucose detection, with a limit of detection (LOD) as low as 0.003 and 0.014 mM, respectively, which was much lower than for previously reported paper-based colorimetric assays. The proposed assays were successfully applied to uric acid and glucose detection in real serum samples. Furthermore, the enhanced analytical performance of the proposed method allowed the non-invasive detection of glucose levels in tear samples, which holds great potential for point-of-care analysis. Graphical abstract ᅟ.

Entities:  

Keywords:  Colorimetric assay; Glucose; Paper-based; Smartphone; Uric acid

Mesh:

Substances:

Year:  2018        PMID: 29455281     DOI: 10.1007/s00216-018-0939-4

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  17 in total

1.  Enhanced peroxidase-like activity of platinum nanoparticles decorated on nickel- and nitrogen-doped graphene nanotubes: colorimetric detection of glucose.

Authors:  Neda Fakhri; Foad Salehnia; Sepideh Mohammad Beigi; Sajjad Aghabalazadeh; Morteza Hosseini; Mohammad Reza Ganjali
Journal:  Mikrochim Acta       Date:  2019-05-28       Impact factor: 5.833

Review 2.  Strategies for the detection of target analytes using microfluidic paper-based analytical devices.

Authors:  Wei Zheng; Kan Wang; Hao Xu; Chujun Zheng; Bo Cao; Qi Qin; Qinghui Jin; Daxiang Cui
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

3.  Biosensors for Personal Mobile Health: A System Architecture Perspective.

Authors:  Siddarth Arumugam; David A M Colburn; Samuel K Sia
Journal:  Adv Mater Technol       Date:  2019-11-20

Review 4.  Recent advances in nephropathy biomarker detections using paper-based analytical devices.

Authors:  Akhmad Sabarudin; Setyawan P Sakti; Hani Susianti; Nur Samsu; Ika O Wulandari; Yudit Oktanella; Dewi Anggraeni
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

Review 5.  Nanozyme-based colorimetric biosensor with a systemic quantification algorithm for noninvasive glucose monitoring.

Authors:  Hee-Jae Jeon; Hyung Shik Kim; Euiheon Chung; Dong Yun Lee
Journal:  Theranostics       Date:  2022-09-07       Impact factor: 11.600

Review 6.  Smartphone-based mobile biosensors for the point-of-care testing of human metabolites.

Authors:  Meiying Zhang; Xin Cui; Nan Li
Journal:  Mater Today Bio       Date:  2022-04-08

7.  Harnessing a previously unidentified capability of bacterial allosteric transcription factors for sensing diverse small molecules in vitro.

Authors:  Jiaqian Cao; Yongpeng Yao; Keqiang Fan; Gaoyi Tan; Wensheng Xiang; Xuekui Xia; Shanshan Li; Weishan Wang; Lixin Zhang
Journal:  Sci Adv       Date:  2018-11-28       Impact factor: 14.136

8.  A Portable Smartphone-Based Sensing System Using a 3D-Printed Chip for On-Site Biochemical Assays.

Authors:  Feiyi Wu; Min Wang
Journal:  Sensors (Basel)       Date:  2018-11-16       Impact factor: 3.576

Review 9.  From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics).

Authors:  Dionysios C Christodouleas; Balwinder Kaur; Parthena Chorti
Journal:  ACS Cent Sci       Date:  2018-11-20       Impact factor: 14.553

Review 10.  Smartphone-based clinical diagnostics: towards democratization of evidence-based health care.

Authors:  I Hernández-Neuta; F Neumann; J Brightmeyer; T Ba Tis; N Madaboosi; Q Wei; A Ozcan; M Nilsson
Journal:  J Intern Med       Date:  2018-09-12       Impact factor: 8.989

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.