Literature DB >> 29454540

Asymmetric cellulose triacetate is a safe and effective alternative for online haemodiafiltration.

Marta Albalate Ramón1, Patricia Martínez Miguel2, Lourdes Bohorquez3, Patricia de Sequera4, Hanane Bouarich2, Rafael Pérez-García4, Diego Rodríguez Puyol2, Guillermina Barril5, Jose Antonio Sánchez Tomero5, Martin Giorgi5, Manuel Rafael Ramirez Chamond3.   

Abstract

BACKGROUND: In post-dilution haemodiafiltration only synthetic membranes have been used to date. Asymmetric cellulose triacetate (ATA™) is now available, whose characteristics are suitable for this technique.
OBJECTIVES: To describe the in vivo performance and behaviour of this membrane, to identify its depurative effectiveness, use in clinical practice and its biocompatibility, both acute and after one month of treatment.
METHODS: Observational prospective study of 23 patients who were dialysed for 4 weeks using an ATA™ membrane and who maintained their prior regimen.
RESULTS: A total of 287 sessions were performed and 264 complete sessions were collected. With an effective time of 243.7 (17.6) min and a mean blood flow of 371.7 (23) ml/min, an average Kt of 56.3 (5.3) l was observed, as well as a convection volume of 27.1 (4.2) l, a filtration fraction of 29.9 (3.7) %, a urea reduction ratio (RR) of 81 (5.2) %, a creatinine RR of 74.7 (4.6) %, a β2-microglobulin RR of 76.5 (4.8) % and a retinol binding protein RR of 18.6 (7.6) %. There were no technical problems or alarms. Changing the heparin dosage was not necessary. No increases in C3a or C5a concentrations or leukopenia were observed in the first 30min of the session. Neither the monocyte subpopulations nor IL-β1 or IL-6 were significantly altered after one month of treatment.
CONCLUSIONS: The new ATA™ membrane achieves adequate Kt and convection volume, without technical problems and with good biocompatibility and inflammatory profiles. It is therefore a valid option for post-dilution haemodiafiltration, particularly in patients allergic to synthetic membranes.
Copyright © 2018 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Adecuación; Biocompatibilidad; Biocompatibility; Cellulose triacetate; Hemodiafiltración en línea; Inflamación; Inflammation; Online haemodiafiltration; Suitability; Triacetato de celulosa

Mesh:

Substances:

Year:  2018        PMID: 29454540     DOI: 10.1016/j.nefro.2017.11.015

Source DB:  PubMed          Journal:  Nefrologia (Engl Ed)        ISSN: 2013-2514


  2 in total

1.  The removal capacity of asymmetric cellulose triacetate during post-dilution online hemodiafiltration.

Authors:  Alba Santos; Nicolás Macías; Leonidas Cruzado; Almudena Vega
Journal:  Kidney Res Clin Pract       Date:  2021-04-14

2.  Toxin Removal and Inflammatory State Modulation during Online Hemodiafiltration Using Two Different Dialyzers (TRIAD2 Study).

Authors:  Gabriele Donati; Maria Cappuccilli; Chiara Donadei; Matteo Righini; Anna Scrivo; Lorenzo Gasperoni; Fulvia Zappulo; Gaetano La Manna
Journal:  Methods Protoc       Date:  2021-04-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.