Literature DB >> 29450545

Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method.

Mingue Kim1, Youngsub Eom1, Hwa Lee1, Young-Woo Suh1, Jong Suk Song1, Hyo Myung Kim1.   

Abstract

Purpose: To evaluate the accuracy of IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio.
Methods: Nine hundred twenty-eight eyes from 928 reference subjects and 158 eyes from 158 cataract patients who underwent phacoemulsification surgery were enrolled. Adjusted corneal power of cataract patients was calculated using the fictitious refractive index that was obtained from the geometric mean posterior/anterior corneal curvature radii ratio of reference subjects and adjusted anterior and predicted posterior corneal curvature radii from conventional keratometry (K) using the posterior/anterior corneal curvature radii ratio. The median absolute error (MedAE) based on the adjusted corneal power was compared with that based on conventional K in the Haigis and SRK/T formulae.
Results: The geometric mean posterior/anterior corneal curvature radii ratio was 0.808, and the fictitious refractive index of the cornea for a single Scheimpflug camera was 1.3275. The mean difference between adjusted corneal power and conventional K was 0.05 diopter (D). The MedAE based on adjusted corneal power (0.31 D in the Haigis formula and 0.32 D in the SRK/T formula) was significantly smaller than that based on conventional K (0.41 D and 0.40 D, respectively; P < 0.001 and P < 0.001, respectively). The percentage of eyes with refractive prediction error within ± 0.50 D calculated using adjusted corneal power (74.7%) was significantly greater than that obtained using conventional K (62.7%) in the Haigis formula (P = 0.029). Conclusions: IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio provided more accurate refractive outcomes than calculation using conventional K.

Entities:  

Mesh:

Year:  2018        PMID: 29450545     DOI: 10.1167/iovs.17-22405

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  8 in total

1.  Using the posterior to anterior corneal curvature radii ratio to minimize the risk of a postoperative hyperopic shift after Descemet membrane endothelial keratoplasty.

Authors:  Raphael Diener; Nicole Eter; Maged Alnawaiseh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-01-31       Impact factor: 3.117

2.  Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses.

Authors:  Jung Wan Kim; Youngsub Eom; Wonkyung Park; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-28       Impact factor: 3.535

3.  Outcomes of the Haigis-L formula for calculating intraocular lens power in extreme long axis eyes after myopic laser in situ keratomileusis.

Authors:  Xiaoling Fang; Shenyu Ben; Yiping Dong; Xia Chen; Wenwen Xue; Yulan Wang
Journal:  Eye (Lond)       Date:  2021-06-11       Impact factor: 4.456

4.  The impact of cataract progression on accuracy of intraocular lens power measurement.

Authors:  Lin Leng; Honglei Li; Min Yin; Han Gao; Ting Shao; Keli Long
Journal:  PLoS One       Date:  2021-02-10       Impact factor: 3.240

5.  A Multicenter Study of the Distribution Pattern of Posterior-To-Anterior Corneal Curvature Radii Ratio in Chinese Myopic Patients.

Authors:  Changting Tang; Qiaowei Wu; Baoyi Liu; Guanrong Wu; Jing Fan; Yijun Hu; Honghua Yu
Journal:  Front Med (Lausanne)       Date:  2021-12-20

6.  Intraocular lens power calculation after two different successive corneal refractive surgeries.

Authors:  Zongsheng Zeng; Xiangyu Ye; Qingzhong Chen; Changkai Jia; Guangbin Zhang
Journal:  Am J Ophthalmol Case Rep       Date:  2022-04-26

7.  Optimizing intraocular lens power calculation using adjusted conventional keratometry for cataract surgery combined with Descemet membrane endothelial keratoplasty.

Authors:  Raphael Diener; Maximilian Treder; Jost Lennart Lauermann; Nicole Eter; Maged Alnawaiseh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-03-08       Impact factor: 3.535

8.  Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature.

Authors:  Chenguang Zhang; Guangzheng Dai; Emmanuel Eric Pazo; Ling Xu; Xianwei Wu; Hongda Zhang; Tiezhu Lin; Wei He
Journal:  PLoS One       Date:  2020-11-20       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.