Literature DB >> 29448290

Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability.

Kristina Imeen Ringe1, Julian A Luetkens2, Rolf Fimmers3, Renate Maria Hammerstingl4, Günter Layer5, Martin H Maurer6, Claas Philip Nähle7, Sabine Michalik8, Peter Reimer9, Christina Schraml10, Andreas G Schreyer11, Patrick Stumpp12, Thomas J Vogl4, Frank K Wacker1, Winfried Willinek13, Guido Mattias Kukuk2.   

Abstract

PURPOSE: To assess the interrater agreement and reliability of experienced abdominal radiologists in the characterization and grading of arterial phase gadoxetate disodium-related respiratory motion artifact on liver MRI.
MATERIALS AND METHODS: This prospective multicenter study was initiated by the working group for abdominal imaging within the German Roentgen Society (DRG), and approved by the local IRB of each participating center. 11 board-certified radiologists independently reviewed 40 gadoxetate disodium-enhanced liver MRI datasets. Motion artifacts in the arterial phase were assessed on a 5-point scale. Interrater agreement and reliability were calculated using the intraclass correlation coefficient (ICC) and Kendall coefficient of concordance (W), with p < 0.05 deemed significant.
RESULTS: The ICC for interrater agreement and reliability were 0.983 (CI 0.973 - 0.990) and 0.985 (CI 0.978 - 0.991), respectively (both p < 0.0001), indicating excellent agreement and reliability. Kendall's W for interrater agreement was 0.865. A severe motion artifact, defined as a mean motion score ≥ 4 in the arterial phase was observed in 12 patients. In these specific cases, a motion score ≥ 4 was assigned by all readers in 75 % (n = 9/12 cases).
CONCLUSION: Differentiation and grading of arterial phase respiratory motion artifact is possible with a high level of inter-/intrarater agreement and interrater reliability, which is crucial for assessing the incidence of this phenomenon in larger multicenter studies. KEY POINTS: · Inter- and intrarater agreement for motion artifact scoring is excellent among experienced readers.. · Interrater reliability for motion artifact scoring is excellent among experienced readers.. · Characterization of severe motion artifacts proved feasible in this multicenter study.. CITATION FORMAT: · Ringe KI, Luetkens JA, Fimmers R et al. Characterization of Severe Arterial Phase Respiratory Motion Artifact on Gadoxetate Disodium-Enhanced MRI - Assessment of Interrater Agreement and Reliability. Fortschr Röntgenstr 2017; 190: 341 - 347. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29448290     DOI: 10.1055/s-0044-100727

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  1 in total

1.  Respiratory motion artefacts in Gd-EOB-DTPA (Primovist/Eovist) and Gd-DOTA (Dotarem)-enhanced dynamic phase liver MRI after intensified and standard pre-scan patient preparation: A bi-institutional analysis.

Authors:  Christian Wybranski; Florian Siedek; Robert Damm; Angelos Gazis; Ortrud Wenzel; Stefan Haneder; Thorsten Persigehl; Susanne Steinhauser; Maciej Pech; Frank Fischbach; Katharina Fischbach
Journal:  PLoS One       Date:  2020-03-20       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.