Aortic valve replacement using autologous pericardium: single centre experience with the Ozaki technique.

Oliver Reuthebuch1, Luca Koechlin1, Ulrich Schurr1, Martin Grapow1, Jens Fassl2, Friedrich S Eckstein1.   

Abstract

OBJECTIVE: To assess the clinical implementation and report preliminary results of a novel technique called the Ozaki procedure for stentless aortic valve replacement through reconstruction of the valve leaflets from autologous pericardium.
METHOD: Between September 2015 and May 2017 30 patients (20 males, mean ± standard deviation age 66.83 ± 10.55 years) suffering from aortic stenosis (AS, n = 7), aortic regurgitation (AR, n = 12), or a combination of both (AS/AR, n = 11) were assigned for an Ozaki procedure. The glutaraldehyde-treated autologous pericardium was intraoperatively customised and tailored according to individual sinus measurements and appropriate Ozaki templates (CE marked).
RESULTS: Mean and peak preoperative transvalvular pressure gradients in patients with AS were 46.34 ± 14.71 and 78.00 ± 22.54 mm Hg, respectively and effective orifice area was 0.93 ± 0.26 cm2. Ejection fraction was preserved at 57.37 ± 10.33%. Twenty-four valves were tricuspid and 6 bicuspid; 13 patients had concomitant cardiac surgery (coronary artery bypass graft, mitral valve repair, replacement of ascending aorta). Mean ± SD cross-clamp time for replacement only was 85.18 ± 18.10 minutes and perfusion time 104.76 ± 38.52 minutes. Cusp sizes were 27.76 ± 3.52 mm for the left coronary cusp (CC), 28.20 ± 3.51 mm for the right CC and 29.20 ± 3.34 mm for non-CC. Mean and peak postoperative gradients decreased to 8 ± 3.55 and 14.8 ± 6.21 mm Hg, respectively. Mean length of stay on the intensive care unit was 2.19 ± 2.34 days and in-hospital stay was 8.81 ± 2.04 days after isolated Ozaki procedures. No pacemaker had to be implanted after an isolated Ozaki procedure. Thirty-day mortality was 3.33% (n = 1). After 3 months, no patient presented with aortic stenosis, and regurgitation of the substituted valves was graded nil/trace in 85.71%, mild in 10.71%, and moderate in 3.57% of the patients. Ejection fraction remained unchanged at 58.89 ± 11.29%. No reoperation was required within the first 3 months.
CONCLUSION: This aortic valve replacement technique has become available only recently. In our experience, it can be mastered after a relatively short training period, and has become part of our routine clinical toolbox. The use of autologous pericardium in combination with excellent haemodynamics may have the potential to overcome the structural disadvantages of biological aortic valves, to be beneficial in infective endocarditis, and to represent an alternative for patients with small annuli.

Entities:  

Mesh:

Year:  2018        PMID: 29442340     DOI: 10.4414/smw.2018.14591

Source DB:  PubMed          Journal:  Swiss Med Wkly        ISSN: 0036-7672            Impact factor:   2.193


  5 in total

Review 1.  Aortic valve neo-cuspidation using the Ozaki technique for acquired and congenital disease: where does this procedure currently stand?

Authors:  Christopher W Baird; Supreet P Marathe; Pedro J Del Nido
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-01-09

Review 2.  Narrative review of the contemporary surgical treatment of unicuspid aortic valve disease.

Authors:  Maria von Stumm; Tatjana Sequeira-Gross; Johannes Petersen; Shiho Naito; Lisa Müller; Christoph Sinning; Evaldas Girdauskas
Journal:  Cardiovasc Diagn Ther       Date:  2021-04

3.  Echocardiographic and Clinical Follow-up After Aortic Valve Neocuspidization Using Autologous Pericardium.

Authors:  Luca Koechlin; Ulrich Schurr; Jules Miazza; Sebastian Imhof; Markus Maurer; Joachim Erb; Brigitta Gahl; David Santer; Denis Berdajs; Friedrich S Eckstein; Oliver Reuthebuch
Journal:  World J Surg       Date:  2020-09       Impact factor: 3.352

4.  Short-term outcomes of aortic valve neocuspidization for various aortic valve diseases.

Authors:  Gregory Khatchatourov; Mathieu van Steenberghe; Doris Goy; Mathieu Potin; Javier Orrit; François Perret; Nicolas Murith; Jean-Jacques Goy
Journal:  JTCVS Open       Date:  2021-08-26

Review 5.  Aortic Valve Neocuspidization with Glutaraldehyde-Treated Autologous Pericardium (Ozaki Procedure) - A Promising Surgical Technique.

Authors:  Michel Pompeu Barros Oliveira Sá; Álvaro M Perazzo; Konstantin Zhigalov; Roman Komarov; Bakytbek Kadyraliev; Soslan Enginoev; Jürgen Ennker; Aron Frederik Popov; Cesare Quarto; Alexander Weymann; Ricardo Carvalho Lima
Journal:  Braz J Cardiovasc Surg       Date:  2019-12-01