Literature DB >> 2943979

[A false aneurysm caused by rupture of a double velour Dacron graft. A case report].

J Nakajima, T Ikegami, T Ishihara, K Murakami, K Morimoto.   

Abstract

A 71-year-old man was operated for a complete occlusion of the left common iliac artery caused by arteriosclerosis obliterans. Cross-over bypass was performed from the right external iliac artery to the left superficial femoral artery in June 1978, using a Double Velour Dacron graft (Cooley) 8 mm in diameter. In February 1985, the patient noticed the pulsatile mass in his left groin. Angiography showed a false aneurysm at the distal anastomosis of the graft. On operation, 2 aneurysmal dilatations were found on the distal anastomosis. After resection of the aneurysms, the reconstruction was established by EPTFE graft successfully. The resected specimen showed that one of the aneurysms was caused by the anastomotic failure of the distal portion of the graft, but that the other was the false aneurysm caused by rupture of the implanted graft. Two ruptured holes were confirmed to be 20 X 25 mm, 10 X 15 mm in size respectively, 10 mm proximal to the anastomotic aneurysm. Rupture of the Dacron arterial prosthesis is a rare complication. Only 23 cases have been reported in the United States. But some literatures show that the incidence of the failure of the Dacron prosthesis was about 3%. Therefore, we should make a long-term follow-up to the patients implanted Dacron arterial prostheses.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2943979

Source DB:  PubMed          Journal:  Nihon Geka Gakkai Zasshi        ISSN: 0301-4894


  3 in total

1.  Pseudoaneurysm in the Left Groin due to Ruptured Knitted Dacron Graft.

Authors:  Masahiro Ryugo; Takumi Yasugi; Mitsugi Nagashima; Hironori Izutani; Toru Okamura; Fumiaki Shikata; Masashi Kawamura; Kanji Kawachi
Journal:  Ann Vasc Dis       Date:  2011-06-02

2.  Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts.

Authors:  Satoshi Yamamoto; Katsuyuki Hoshina; Hideo Kimura; Hiroyuki Okamoto; Kunihiro Shigematsu; Tetsuro Miyata; Toshiaki Watanabe
Journal:  Surg Today       Date:  2014-04-03       Impact factor: 2.549

Review 3.  Nonanastomotic aneurysm formation in a Dacron arterial graft: report of a case.

Authors:  I Han; H Shigematsu; M Nunokawa; H Matsuzaki; K Iwata; S Nakamura; M Ishimaru; A Sugiura; Y Kobayashi; Y Morioka
Journal:  Surg Today       Date:  1994       Impact factor: 2.549

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.