Literature DB >> 29439600

Initial Experience With the Outback Catheter for Targeted Reentry During Subintimal Angioplasty of the Infragenicular Arteries.

Athanasios Diamantopoulos1,2, Serafino Santonocito1, Narayanan Thulasidasan1, Panos Gkoutzios1, Irfan Ahmed1, Hany Zayed2,3, Konstantinos Katsanos1,2.   

Abstract

PURPOSE: To report use of the Outback reentry device for targeted distal reentry during subintimal recanalization of chronic total occlusions (CTOs) in the infragenicular arteries.
METHODS: During an 18-month period, the Outback device was applied in 10 patients (mean age 71.8±18.8 years; 8 men) to achieve reentry at the infragenicular segment following either unsuccessful spontaneous reentry after subintimal crossing of a CTO or when a targeted reentry was desired. The mean occlusion length was 117.5±101.0 mm. Technical (device) success, overall procedure success, and reentry accuracy are reported, along with any major or minor complications.
RESULTS: The device was technically successful in achieving reentry in 9 of 10 cases; overall procedure success was achieved in 8 owing to heavy calcifications in a distal posterior tibial artery and a distal popliteal artery. The reentry accuracy was 10.8±14.6 mm. There were no major complications and only 3 minor sequelae, including 2 dissections and 1 small perforation; all were treated successfully with stenting.
CONCLUSION: The Outback device has a high technical success rate in achieving targeted true lumen reentry in infragenicular subintimal angioplasty when spontaneous reentry is not possible or a targeted reentry is desirable.

Entities:  

Keywords:  below-the-knee angioplasty; dissection; infrainguinal arteries; perforation; reentry device; subintimal angioplasty; tibial artery

Mesh:

Year:  2018        PMID: 29439600     DOI: 10.1177/1526602818757409

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  4 in total

Review 1.  [Innovations in the endovascular treatment of peripheral arterial disease].

Authors:  Jörg Teßarek; Alexander Oberhuber
Journal:  Gefasschirurgie       Date:  2021-08-13

2.  Development of a Magnetic Kissing Guidewire and Animal Experiment: a Preliminary Study.

Authors:  Xiangtao Li; Huan Zhang; Mingyi Zhang; Shuai Niu; Fuxian Zhang
Journal:  J Cardiovasc Transl Res       Date:  2020-03-09       Impact factor: 4.132

3.  Retrograde insertion of the outback reentry device from a tibial artery for complex infrainguinal recanalization.

Authors:  Lorenzo Patrone; Ondrej Stehno
Journal:  CVIR Endovasc       Date:  2019-12-30

4.  Targeted tibio-peroneal re-entry during subintimal revascularization using the Outback® catheter.

Authors:  K Rippel; H Ruhnke; B Jehs; J Decker; T Kroencke; C Scheurig-Muenkler
Journal:  CVIR Endovasc       Date:  2021-01-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.