Literature DB >> 29430146

Fabrication of a magnetic holder for the removal of ocular prosthesis.

D Bheemalingeswara Rao1, Akkottillam Malya1, K Bharat Chandra1, K Chandrasekharan Nair1.   

Abstract

Long-term success of ocular prostheses is dictated by the retentive quality which is usually ensured by maximum possible extension into the sulcus of the eyelids. Majority of the patients experience difficulty during manual placement and removal of the prosthesis, especially when the sulcus is very deep. Ocular prosthesis is commonly removed with fingers or suction cups. Although the suction cups are popular, its efficiency lasts only for a limited period. Moreover, it is not easily available in the rural Indian market. This article presents the design of a magnetic instrument for the placement and removal of the ocular prosthesis.

Entities:  

Keywords:  Magnetic holder; metallic insert; ocular prosthesis

Year:  2018        PMID: 29430146      PMCID: PMC5799973          DOI: 10.4103/jips.jips_208_17

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  6 in total

1.  Causes of enucleation in Northern India (1995-2005).

Authors:  A Bal; H Mohan; S Chabbra; S Sood
Journal:  Eur J Ophthalmol       Date:  2007 Jul-Aug       Impact factor: 2.597

2.  A Simplified Method to Fabricate a Pneumatic Ocular Prosthesis for Large Ocular Defects.

Authors:  Himanshi Aggarwal; Pradeep Kumar; Raghuwar Dayal Singh
Journal:  J Indian Prosthodont Soc       Date:  2014-07-08

3.  Enucleation in a tertiary eye care centre in India: prevalence, current indications and clinicopathological correlation.

Authors:  G K Vemuganti; S Jalali; S G Honavar; G C Shekar
Journal:  Eye (Lond)       Date:  2001-12       Impact factor: 3.775

4.  An innovative and simple approach to fabricate a hollow ocular prosthesis with functional lubricant reservoir: A solution to artificial eye comfort.

Authors:  Aditya Anil Kavlekar; Meena Ajay Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2017 Apr-Jun

5.  A simplified approach to rehabilitate an ocular defect: Ocular prosthesis.

Authors:  Darshana Choubisa
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

6.  Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis.

Authors:  Sumeet Jain; Parul Jain
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar
  6 in total