Literature DB >> 29429598

Does the site of the orthotopic neobladder outlet matter? A prospective randomized comparative study.

Ahmed M Moeen1, Ahmed S Safwat2, Mohamed M Gadelmoula1, Seham M Moeen3, Hosny M Behnsawy1, Ahmed A Shahat1, Rabea A Gadelkareem1, Diaa A Hameed1, Hisham M Hammouda1.   

Abstract

BACKGROUND: To compare the results of urethral anastomosis to a button hole and to the lowest part of the anterior suture line during orthotopic neobladder substitution.
METHODS: From January 2012 to December 2015, 87 consecutive male patients with invasive bladder cancer underwent radical cystectomy and Hautmann ileal neobladder. Patients were randomly divided into two groups; group I (44 patients), the outlet was created as a button-hole at the most dependent part of the pouch, group II (43 patients), the lowest 1 cm of the anterior suture line of the pouch was left open as an outlet. Patients were randomly assigned to either group using computer-generated random numbers (JMP, Version 12.0.1; SAS Institute, Cary, NC, USA) via a sealed envelope. The functional outcomes of both groups were compared especially at the urethro-enteric anastomosis.
RESULTS: There were no intraoperative complications. Early postoperative complications occurred in 9 patients (5 in group I and 4 in group II, p = 0.484). Prolonged urinary leakage persisted for 11 and 14 days in 2 patients in group I and 10 and 16 days in 2 patients in group II. Delayed postoperative complications occurred in 11 patients (5 [12.5%] in group I and 6 [15.6%] in group II) (p = 0.711). Three patients developed urethro-enteric strictures (2 in group I and 1 in group II) (p = 0.571).
CONCLUSION: The "non-hole" technique of urethral anastomosis was not associated with a significant increase in the complication rate when compared to the commonly performed "hole" technique.
Copyright © 2018 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

Entities:  

Keywords:  Button-hole; Cystectomy; Neobladder; Outlet; Urethro-enteric anastomosis

Mesh:

Year:  2018        PMID: 29429598     DOI: 10.1016/j.ejso.2018.01.094

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  2 in total

1.  Long-term outcome of spiral ileal neobladder with orthotopic ureteral reimplantation.

Authors:  Huan Zhong; Yuefan Shen; Zixiang Yao; Xiaonong Chen; Jianguo Gao; Anping Xiang; Weigao Wang
Journal:  Int Urol Nephrol       Date:  2019-09-27       Impact factor: 2.370

2.  Functional results of hautmann neobladder with chimney modification and wallace ureteroileal anastomosis: initial experience with 22 patients.

Authors:  Dejan Djordjevic; Marko Vukovic
Journal:  Int Braz J Urol       Date:  2021 Mar-Apr       Impact factor: 1.541

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.