Lorenzo Valerio1, Jawaad Sheriff2, Phat L Tran3, William Brengle3, Alberto Redaelli4, Gianfranco B Fiore4, Federico Pappalardo5, Danny Bluestein2, Marvin J Slepian6. 1. Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy; Department of Cardiothoracic Anesthesia and Intensive Care, Istituto Scientifico San Raffaele, Milan, Italy. 2. Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA. 3. Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ, USA. 4. Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy. 5. Department of Cardiothoracic Anesthesia and Intensive Care, Istituto Scientifico San Raffaele, Milan, Italy. 6. Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA; Department of Biomedical Engineering, Sarver Heart Center, University of Arizona, Tucson, AZ, USA; Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA. Electronic address: slepian@email.arizona.edu.
Abstract
INTRODUCTION: Continuous flow ventricular assist devices (cfVADs) continue to be limited by thrombotic complications associated with disruptive flow patterns and supraphysiologic shear stresses. Patients are prescribed complex antiplatelet therapies, which do not fully prevent recurrent thromboembolic events. This is partially due to limited data on antiplatelet efficacy under cfVAD-associated shear conditions. MATERIALS AND METHODS: We investigated the efficacy of antiplatelet drugs directly acting on three pathways: (1) cyclooxygenase (aspirin), (2) phosphodiesterase (dipyridamole, pentoxifylline, cilostazol), and (3) glycoprotein IIb-IIIa (eptifibatide). Gel-filtered platelets treated with these drugs were exposed for 10min to either constant shear stresses (30dyne/cm2 and 70dyne/cm2) or dynamic shear stress profiles extracted from simulated platelet trajectories through a cfVAD (Micromed DeBakey). Platelet activation state (PAS) was measured using a modified prothrombinase-based assay, with drug efficacy quantified based on PAS reduction compared to untreated controls. RESULTS AND CONCLUSIONS: Significant PAS reduction was observed for all drugs after exposure to 30dyne/cm2 constant shear stress, and all drugs but dipyridamole after exposure to the 30th percentile shear stress waveform of the cfVAD. However, only cilostazol was significantly effective after 70dyne/cm2 constant shear stress exposure, though no significant reduction was observed upon exposure to median shear stress conditions in the cfVAD. These results, coupled with the persistence of reported clinical thrombotic complication, suggest the need for the development of new classes of drugs that are especially designed to mitigate thrombosis in cfVAD patients, while reducing or eliminating the risk of bleeding.
INTRODUCTION: Continuous flow ventricular assist devices (cfVADs) continue to be limited by thrombotic complications associated with disruptive flow patterns and supraphysiologic shear stresses. Patients are prescribed complex antiplatelet therapies, which do not fully prevent recurrent thromboembolic events. This is partially due to limited data on antiplatelet efficacy under cfVAD-associated shear conditions. MATERIALS AND METHODS: We investigated the efficacy of antiplatelet drugs directly acting on three pathways: (1) cyclooxygenase (aspirin), (2) phosphodiesterase (dipyridamole, pentoxifylline, cilostazol), and (3) glycoprotein IIb-IIIa (eptifibatide). Gel-filtered platelets treated with these drugs were exposed for 10min to either constant shear stresses (30dyne/cm2 and 70dyne/cm2) or dynamic shear stress profiles extracted from simulated platelet trajectories through a cfVAD (Micromed DeBakey). Platelet activation state (PAS) was measured using a modified prothrombinase-based assay, with drug efficacy quantified based on PAS reduction compared to untreated controls. RESULTS AND CONCLUSIONS: Significant PAS reduction was observed for all drugs after exposure to 30dyne/cm2 constant shear stress, and all drugs but dipyridamole after exposure to the 30th percentile shear stress waveform of the cfVAD. However, only cilostazol was significantly effective after 70dyne/cm2 constant shear stress exposure, though no significant reduction was observed upon exposure to median shear stress conditions in the cfVAD. These results, coupled with the persistence of reported clinical thrombotic complication, suggest the need for the development of new classes of drugs that are especially designed to mitigate thrombosis in cfVAD patients, while reducing or eliminating the risk of bleeding.
Authors: Vivian X Du; Dana Huskens; Coen Maas; Raed Al Dieri; Philip G de Groot; Bas de Laat Journal: Semin Thromb Hemost Date: 2013-12-19 Impact factor: 4.180
Authors: David Feldman; Salpy V Pamboukian; Jeffrey J Teuteberg; Emma Birks; Katherine Lietz; Stephanie A Moore; Jeffrey A Morgan; Francisco Arabia; Mary E Bauman; Hoger W Buchholz; Mario Deng; Marc L Dickstein; Aly El-Banayosy; Tonya Elliot; Daniel J Goldstein; Kathleen L Grady; Kylie Jones; Katarzyna Hryniewicz; Ranjit John; Annemarie Kaan; Shimon Kusne; Matthias Loebe; M Patricia Massicotte; Nader Moazami; Paul Mohacsi; Martha Mooney; Thomas Nelson; Francis Pagani; William Perry; Evgenij V Potapov; J Eduardo Rame; Stuart D Russell; Erik N Sorensen; Benjamin Sun; Martin Strueber; Abeel A Mangi; Michael G Petty; Joseph Rogers Journal: J Heart Lung Transplant Date: 2013-02 Impact factor: 10.247
Authors: Randall C Starling; Nader Moazami; Scott C Silvestry; Gregory Ewald; Joseph G Rogers; Carmelo A Milano; J Eduardo Rame; Michael A Acker; Eugene H Blackstone; John Ehrlinger; Lucy Thuita; Maria M Mountis; Edward G Soltesz; Bruce W Lytle; Nicholas G Smedira Journal: N Engl J Med Date: 2013-11-27 Impact factor: 91.245
Authors: Alice Sweedo; Lisa M Wise; Yana Roka-Moiia; Fernando Teran Arce; S Scott Saavedra; Jawaad Sheriff; Danny Bluestein; Marvin J Slepian; John G Purdy Journal: Cell Mol Bioeng Date: 2021-08-25 Impact factor: 3.337