Literature DB >> 29428170

Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling.

Mana Torii1, Toyoki Nakata2, Kazuya Takahashi2, Noboru Kawamura3, Hidemasa Shimpo2, Chikahiro Ohkubo2.   

Abstract

PURPOSE: With computer-aided design and computer-aided manufacturing (CAD/CAM), the study was conducted to create a removable partial denture (RPD) framework using repeated laser sintering rather than milling and casting techniques. This study experimentally evaluated the CAM clasp and compared it to a conventional cast clasp.
METHODS: After the tooth die was scanned, an Akers clasp was designed using CAD with and without 50μm of digital relief on the occlusal surface of the tooth die. Cobalt-chromium (Co-Cr) alloy clasps were fabricated using repeated laser sintering (RLS) and milling as one process simultaneously (hybrid manufacturing; HM). The surface roughness of the rest region, gap distances between clasp and tooth die, initial retentive forces, and changes of retentive forces up to 10,000 insertion/removal cycles were measured before and after heat treatment. The HM clasp was compared to the cast clasp and the clasp made by repeated laser sintering only without a milling process.
RESULTS: The HM clasp surface was smoother than those of cast and RLS clasps. With the digital relief, the fitness accuracy of the HM clasp improved. The retentive forces of the HM clasps with relief and after heat treatment were significantly greater than for the cast clasp. HM clasps demonstrated a constant or slight decrease of retention up to 10,000 cycles.
CONCLUSIONS: HM clasp exhibited better fitness accuracy and retentive forces. The possibility of clinically using HM clasps as well as conventional cast clasps can be suggested.
Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CAD/CAM; Clasp; Heat treatment; Relief; Retentive force

Mesh:

Substances:

Year:  2018        PMID: 29428170     DOI: 10.1016/j.jpor.2018.01.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  5 in total

Review 1.  A Scoping Review on the Accuracy of Fit of Removable Partial Dentures in a Developing Digital Context.

Authors:  Noor Al Mortadi; Karem H Alzoubi; Robert Williams
Journal:  Clin Cosmet Investig Dent       Date:  2020-11-19

2.  Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging.

Authors:  Felicitas Mayinger; Danka Micovic; Andreas Schleich; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-16       Impact factor: 3.573

3.  The influence mechanism of nano-alumina content in semi-solid ceramic precursor fluid on the forming performance via a light-cured 3D printing method.

Authors:  Kepeng Yang; Sanqiang Xu; Bailu Li
Journal:  RSC Adv       Date:  2020-11-13       Impact factor: 4.036

Review 4.  3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing.

Authors:  Josef Schweiger; Daniel Edelhoff; Jan-Frederik Güth
Journal:  J Clin Med       Date:  2021-05-07       Impact factor: 4.964

5.  Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?

Authors:  Danka Micovic; Felicitas Mayinger; Sebastian Bauer; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2020-10-07       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.