Comparison of the pharmacodynamics of protamine zinc insulin and insulin degludec and validation of the continuous glucose monitoring system iPro2 in healthy cats.

Elena Salesov1, Eric Zini2, Angelina Riederer2, Thomas A Lutz3, Claudia E Reusch2.   

Abstract

With the aim to improve current therapeutic and monitoring options for diabetic cats, the present study compared pharmacodynamic parameters of protamine zinc insulin (PZI) and insulin degludec and validated the continuous glucose monitoring system (CGMS) iPro2 with Sof-sensor and Enlite-sensor focusing on the low glycemic range. Three doses (0.1, 0.2 and 0.3IU/kg) of the two insulin preparations and the CGMS iPro2 with two different sensors were tested in six healthy cats. After each insulin administration, onset of action, time to glucose nadir and duration of action were calculated by measuring glucose concentrations with a portable blood glucose meter (PBGM). After sensor placement, paired PBGM and sensor glucose measurements were done and analytical and clinical accuracy were calculated according to the ISO 15197:2013 criteria. Onset of action, time to glucose nadir and glucose nadir were similar for both insulin formulations. Duration of action of insulin degludec was significantly longer than those of PZI at 0.1IU/kg (P=0.043) and 0.2IU/kg (P=0.043). Overall, 166/191 (87%) Sof-sensor measurements and 106/121 (88%) Enlite-sensor measurements met ISO criteria for analytical accuracy, and all sensor measurements fulfilled ISO criteria for clinical accuracy. Insulin degludec was well tolerated in healthy cats and showed longer duration of action than PZI. Further studies on the use of insulin degludec in diabetic cats might be recommended. Both sensors had good clinical accuracy, when used with the CGMS iPro2, but the analytical accuracy was below the minimum set by ISO 15197:2013.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Continuous glucose monitoring system; Enlite-sensor; Insulin degludec; Protamine zinc insulin; Sof-sensor; iPro2

Mesh:

Substances:

Year:  2018        PMID: 29421488     DOI: 10.1016/j.rvsc.2018.01.019

Source DB:  PubMed          Journal:  Res Vet Sci        ISSN: 0034-5288            Impact factor:   2.534


  3 in total

1.  Comparison of Insulins Glargine and Degludec in Diabetic Rhesus Macaques (Macaca mulatta) with CGM Devices.

Authors:  Samantha C Puglisi; Alexis L Mackiewicz; Amir Ardeshir; Laura M Garzel; Kari L Christe
Journal:  Comp Med       Date:  2021-05-25       Impact factor: 0.982

2.  Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.

Authors:  Marieke Knies; Erik Teske; Hans Kooistra
Journal:  J Feline Med Surg       Date:  2022-06-28       Impact factor: 1.971

3.  Glucose concentrations after insulin-induced hypoglycemia and glycemic variability in healthy and diabetic cats.

Authors:  Eric Zini; Elena Salesov; Perrine Dupont; Laura Moretto; Barbara Contiero; Thomas A Lutz; Claudia E Reusch
Journal:  J Vet Intern Med       Date:  2018-03-30       Impact factor: 3.333

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.