Literature DB >> 29421026

Analysis of four sulfonylurea herbicides in cereals using modified Quick, Easy, Cheap, Effective, Rugged, and Safe sample preparation method coupled with liquid chromatography-tandem mass spectrometry.

Yanxia Ni1, Huan Yang1, Hantong Zhang1, Qiao He1, Siqi Huang1, Meiling Qin1, Shuangshuang Chai1, Huanhuan Gao1, Youning Ma2.   

Abstract

A modified Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) sample preparation method, coupled with liquid chromatography-electrospray ionization tandem mass spectrometry, has been developed for the simultaneous analysis of four commonly used sulfonylurea herbicides, ethoxysulfuron, halosulfuron-methyl, mesosulfuron-methyl and orthosulfamuron, in rice, maize, wheat and soybean. Adsorption of the analytes onto the primary-secondary amine used in the clean-up step was avoided by using 1% formic acid in acetonitrile as the extraction solvent to maintain the acidic herbicides in a non-ionized state. Trueness studies were carried out at three levels (2.5, 25 and 250 μg/kg for ethoxysulfuron and 5, 50 and 500 μg/kg for the other three analytes). Promising trueness (70.2%-119.8%) was achieved for all herbicides in all matrices after clean-up, with relative standard deviations (RSDr) < 18.6%. Satisfactory matrix effects (-19.7% to 14.8%) were also obtained. Good linearity of the calibration curves was achieved, with determination coefficients (r) ≥ 0.9956, when the concentration of ethoxysulfuron was in the range 0.5-50 μg/L and that of the other three analytes was in the range 1.0-500 μg/L. The RSDwR for within-laboratory reproducibility was 5.7%. The validated method was successfully used to analyze real samples.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cereals; High-performance liquid chromatography-electro-spray ionization-tandem mass spectrometry; Modified QuEChERS method; Primary-secondary amine; Sulfonylurea herbicides

Mesh:

Substances:

Year:  2018        PMID: 29421026     DOI: 10.1016/j.chroma.2018.01.017

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  A "half" core-shell magnetic nanohybrid composed of zeolitic imidazolate framework and graphitic carbon nitride for magnetic solid-phase extraction of sulfonylurea herbicides from water samples followed by LC-MS/MS detection.

Authors:  Yan Qi; Mengfei Wan; A M Abd El-Aty; Hui Li; Liping Cao; Yongxin She; Yong Shao; Fen Jin; Shanshan Wang; Jing Wang
Journal:  Mikrochim Acta       Date:  2020-04-20       Impact factor: 5.833

2.  A magnetic graphene-like MoS2 nanocomposite for simultaneous preconcentration of multi-residue herbicides prior to UHPLC with ion trap mass spectrometric detection.

Authors:  Yanfen Zhou; Mengxin Zhao; Zhe Meng; Zelan Wang; Xiuqin Men; Jiguang Li; Heping Li; Jinhui Yang
Journal:  Mikrochim Acta       Date:  2019-07-02       Impact factor: 5.833

3.  Simultaneous determination of 114 pesticides in complex Chinese herbal medicine Fritillaria using ordered mesoporous carbon CMK-3 as a reversed-dispersive solid phase extraction sorbent.

Authors:  Tong Wu; Peipei Qi; Jiao Wang; Zhiwei Wang; Shanshan Di; Hao Xu; Huiyu Zhao; Changshan Zhao; Xinquan Wang
Journal:  RSC Adv       Date:  2021-01-20       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.