Literature DB >> 29415565

Effect of Mannitol on Ultrasonographically Measured Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure During Robot-Assisted Laparoscopic Prostatectomy with Pneumoperitoneum and the Trendelenburg Position.

In-Jung Jun1, Myong Kim2, Joonho Lee3, Se-Ung Park3, Jai-Hyun Hwang3, Jun Hyuk Hong2, Young-Kug Kim3.   

Abstract

INTRODUCTION: CO2 pneumoperitoneum and the steep Trendelenburg position during robot-assisted laparoscopic prostatectomy (RALP) can increase intracranial pressure (ICP). Mannitol is widely used to treat increased ICP. However, no studies to date have specifically evaluated the effect of mannitol on ICP in patients undergoing RALP. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) is considered a reliable technique to noninvasively evaluate the ICP. Therefore, this study compared ONSDs as a surrogate for ICP before and after mannitol administration in prostate cancer patients undergoing RALP.
METHODS: Mannitol (0.5 g/kg) was administered after pneumoperitoneum establishment and shifting to the Trendelenburg position. ONSDs were measured at six predetermined time points: 10 minutes after anesthesia induction (T0); 5 minutes after pneumoperitoneum and the Trendelenburg position before mannitol administration (T1); 30 minutes (T2), 60 minutes (T3), and 90 minutes (T4) after completion of mannitol administration during pneumoperitoneum and the Trendelenburg position; and at skin closure in the supine position (T5). Moreover, intraoperative hemodynamic and respiratory variables were evaluated simultaneously.
RESULTS: Thirty-six patients were analyzed. ONSDs were significantly lower at T2, T3, and T4 than at T1 (all p < 0.001), with the greatest decrease observed at T4 compared with T1 (4.46 ± 0.2 mm vs 4.81 ± 0.3 mm, p < 0.001). Regional cerebral oxygen saturation, cardiac output, corrected flow time, peak velocity, body temperature, arterial CO2 partial pressure, peak airway pressure, plateau airway pressure, dynamic compliance, and static compliance were not significantly different during pneumoperitoneum and the Trendelenburg position; however, mean arterial blood pressure and heart rate were significantly different.
CONCLUSIONS: Mannitol decreases the ONSD in patients undergoing RALP with CO2 pneumoperitoneum and the steep Trendelenburg position. This result provides useful information on the beneficial effects of mannitol administration on prostate cancer patients who may develop increased ICP during RALP.

Entities:  

Keywords:  mannitol; optic nerve sheath diameter; robot-assisted laparoscopic prostatectomy

Mesh:

Substances:

Year:  2018        PMID: 29415565     DOI: 10.1089/end.2017.0828

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  7 in total

1.  Effect of dexmedetomidine on intracranial pressure in patients undergoing gynecological laparoscopic surgery in Trendelenburg position through ultrasonographic measurement of optic nerve sheath diameter.

Authors:  Ting Zhu; Chen Yuan; Meijuan Qian; Lihong Zhao; Hui Li; Yang Xie
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

Review 2.  The effect of laparoscopy on intracranial pressure as measured by optic nerve sheath diameter: A review.

Authors:  Kevin G Mitchell; Ryan B Appleby; Melissa D Sinclair; Ameet Singh
Journal:  Can Vet J       Date:  2022-04       Impact factor: 1.075

3.  Comparison of the Effects of Propofol and Sevoflurane Anesthesia on Optic Nerve Sheath Diameter in Robot-Assisted Laparoscopic Gynecology Surgery: A Randomized Controlled Trial.

Authors:  Jung Eun Kim; Seong Yoon Koh; In-Jung Jun
Journal:  J Clin Med       Date:  2022-04-12       Impact factor: 4.964

4.  Propofol attenuates the increase of sonographic optic nerve sheath diameter during robot-assisted laparoscopic prostatectomy: a randomized clinical trial.

Authors:  Jihion Yu; Jun Hyuk Hong; Jun-Young Park; Jai-Hyun Hwang; Seong-Sik Cho; Young-Kug Kim
Journal:  BMC Anesthesiol       Date:  2018-06-20       Impact factor: 2.217

5.  Dexmedetomidine attenuates the increase of ultrasonographic optic nerve sheath diameter as a surrogate for intracranial pressure in patients undergoing robot-assisted laparoscopic prostatectomy: A randomized double-blind controlled trial.

Authors:  Jihion Yu; Jun-Young Park; Doo-Hwan Kim; Gi-Ho Koh; Wonyeong Jeong; Eunkyul Kim; Jun Hyuk Hong; Jai-Hyun Hwang; Young-Kug Kim
Journal:  Medicine (Baltimore)       Date:  2019-08       Impact factor: 1.817

6.  Brain-Relaxing Effect of Different Diuretic Regimens in Supratentorial Tumor Surgery: A Comparative Study Guided by Optic Nerve Sheath Diameter.

Authors:  Mohamed Adel Aboelela; Alrefaey Kandeel Alrefaey
Journal:  Anesth Essays Res       Date:  2021-03-22

7.  Effects of Increased Optic Nerve Sheath Diameter on Inadequate Emergence from Anesthesia in Patients Undergoing Robot-Assisted Laparoscopic Prostatectomy: A Prospective Observational Study.

Authors:  Yu Jeong Bang; Heejoon Jeong; Burn Young Heo; Byung Seop Shin; Woo Seog Sim; Duk-Kyung Kim; Sang Hyun Lee; Ji Su Kim; Young Hee Shin
Journal:  Diagnostics (Basel)       Date:  2021-12-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.