Literature DB >> 29414088

Ru(bpy)32+-Silica@Poly-L-lysine-Au as labels for electrochemiluminescence lysozyme aptasensor based on 3D graphene.

Fang-Kai Du1, Hui Zhang1, Xue-Cai Tan2, Jun Yan1, Min Liu1, Xiao Chen1, Ye-Yu Wu1, De-Fen Feng1, Quan-You Chen1, Jian-Mei Cen1, Shao-Gang Liu1, Yu-Qin Qiu1, He-You Han3.   

Abstract

In this work, the feasibility of a novel sensitive electrochemiluminescence aptasensor for the detection of lysozyme using Ru(bpy)32+-Silica@Poly-L-lysine-Au (RuSiNPs@PLL-Au) nanocomposites labeling as an indicator was demonstrated. The substrate electrode of the aptasensor was prepared by depositing gold nanoparticles (AuNPs) on 3D graphene-modified electrode. The lysozyme binding aptamer (LBA) was attached to the 3D graphene/AuNPs electrode through gold-thiol affinity, hybridized with a complementary single-strand DNA (CDNA) of the lysozyme aptamer labeled by RuSiNPs@PLL-Au as an electrochemiluminescence intensity amplifier. Thanks to the synergistic amplification of the 3D graphene, the AuNPs and RuSiNPs@PLL-Au NPs linked to Ru(bpy)32+-ECL further enhanced the ECL intensity of the aptasensor. In presence of lysozyme, the CDNA segment of the self-assembled duplex was displaced by the lysozyme, resulting in decreased electrochemiluminescence signal. Under the optimized conditions, the decrease in electrochemiluminescence intensity varied proportionally with the logarithmic concentration of the lysozyme from 2.25 × 10-12 to 5.0 × 10-8 mol L-1, and the detection limit was estimated to 7.5 × 10-13 mol L-1. The aptasensor was further tested in real samples and found reliable for the detection of lysozyme, thus holding great potential application in food safety researches and bioassay analysis.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  3D graphene; Electrochemiluminescence aptasensor; Lysozyme; Ru(bpy)(3)(2+)-Silica@Poly-L-lysine-Au

Mesh:

Substances:

Year:  2018        PMID: 29414088     DOI: 10.1016/j.bios.2018.01.059

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A chemiluminescence assay for determination of lysozyme based on the use of magnetic alginate-aptamer composition and hemin@HKUST-1.

Authors:  Yanna Lin; Yuanling Sun; Yuxue Dai; Xiaodong Zhu; Hao Liu; Rui Han; Dandan Gao; Chuannan Luo; Xueying Wang
Journal:  Mikrochim Acta       Date:  2020-04-20       Impact factor: 5.833

Review 2.  Luminescent Aptamer-Based Bioassays for Sensitive Detection of Food Allergens.

Authors:  Donato Calabria; Martina Zangheri; Seyedeh Rojin Shariati Pour; Ilaria Trozzi; Andrea Pace; Elisa Lazzarini; Maria Maddalena Calabretta; Mara Mirasoli; Massimo Guardigli
Journal:  Biosensors (Basel)       Date:  2022-08-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.