Simultaneous determination of trimethylamine N-oxide, choline, betaine by UPLC-MS/MS in human plasma: An application in acute stroke patients.

Weibang Yu1, Chuncao Xu1, Guomin Li2, Weipeng Hong1, Ziyi Zhou2, Canxing Xiao1, Yuanqi Zhao2, Yefeng Cai2, Min Huang1, Jing Jin3.   

Abstract

Trimethylamine-N-oxide (TMAO) is derived from the gut microbiome and tissues metabolism of dietary choline and betaine. These molecules are closely related to the development of cardiovascular and cerebrovascular diseases. A rapid, sensitive and accurate method has been developed and validated for the simultaneous determination of trimethylamine N-oxide (TMAO), choline and betaine in human plasma using d9-trimethylamine N-oxide (TMAO), d9-choline, d9-betaine as the internal standard (IS). After methanol precipitation with 10 μL plasma samples, the analytes were extracted and then separated on Amide column (2.1 × 100 mm, 1.7 μm, waters) with an isocratic elution program consisting of acetonitrile-water (containing 10 mM ammonium formate pH = 3.0) at a flow of 400 μL/min. The detection was achieved under the selected reaction monitoring (SRM) scan using positive electrospray ionization (ESI+) in 3 min. The mass transitions monitored were as follows: m/z 76.3 → 58.4 for TMAO, m/z 104.2 → 60.3 for choline, m/z 118.1 → 58.3 for betaine, m/z 85.1 → 66.3 for d9-TMAO, m/z 113.2 → 69.3 for d9-choline, and m/z 127.1 → 67.2 for d9-betaine, respectively. The method has been fully validated for specificity, lower limit of quantification, linearity, stability, intra- and inter-day accuracy and precision. This assay combines simple sample processing with a short run time and small plasma volumes, making it well suited for high-throughput routine clinical or research purposes. The newly developed method was successfully applied to the patients (n = 220) suffered from acute stroke, and the concentration of choline was firstly found to be closely related with the prognosis of these patients.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Betaine; Choline; Plasma concentration; Stroke; Trimethylamine N-oxide; UPLC–MS/MS

Mesh:

Substances:

Year:  2018        PMID: 29414011     DOI: 10.1016/j.jpba.2018.01.049

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  7 in total

1.  Application value of UPLC-MS/MS in detecting serum concentration of anti-schizophrenic drugs in patients with mental illnes.

Authors:  Shaochang Wu; Guidong Zhu; Dajin Zhou; Hongtao Xu; Longyou Zhao
Journal:  Am J Transl Res       Date:  2021-05-15       Impact factor: 4.060

2.  A New Light on Vitamin D in Obesity: A Novel Association with Trimethylamine-N-Oxide (TMAO).

Authors:  Luigi Barrea; Giovanna Muscogiuri; Giuseppe Annunziata; Daniela Laudisio; Giulia de Alteriis; Gian Carlo Tenore; Annamaria Colao; Silvia Savastano
Journal:  Nutrients       Date:  2019-06-10       Impact factor: 5.717

3.  A validated simple LC-MS/MS method for quantifying trimethylamine N-oxide (TMAO) using a surrogate matrix and its clinical application.

Authors:  Yufei Li; Jihyun Kang; Yujin Lee; Jae-Yong Chung; Joo-Youn Cho
Journal:  Transl Clin Pharmacol       Date:  2021-11-23

4.  Circulating choline is associated with coronary artery stenosis in patients with hypertension: A cross-sectional study of Chinese adults.

Authors:  Fei Guo; Xueting Qiu; Yuanting Zhu; Zhirong Tan; Zhenyu Li; Dongsheng Ouyang
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-09-23       Impact factor: 3.738

5.  Association of the Chronotype Score with Circulating Trimethylamine N-Oxide (TMAO) Concentrations.

Authors:  Luigi Barrea; Giovanna Muscogiuri; Gabriella Pugliese; Chiara Graziadio; Maria Maisto; Francesca Pivari; Andrea Falco; Gian Carlo Tenore; Annamaria Colao; Silvia Savastano
Journal:  Nutrients       Date:  2021-05-14       Impact factor: 5.717

6.  Plasma Choline as a Diagnostic Biomarker in Slow Coronary Flow.

Authors:  Yuan-Ting Zhu; Ling-Ping Zhu; Zhen-Yu Wang; Xue-Ting Qiu; Wan-Zhou Wu; Wei-Wang Liu; Yu-Yu Feng; Wen-Kai Xiao; Xin Luo; Zhen-Yu Li; Chuan-Chang Li
Journal:  Cardiol Res Pract       Date:  2020-01-25       Impact factor: 1.866

7.  Simultaneous quantification of trimethylamine N-oxide, trimethylamine, choline, betaine, creatinine, and propionyl-, acetyl-, and L-carnitine in clinical and food samples using HILIC-LC-MS.

Authors:  Mohammed E Hefni; Maria Bergström; Torbjörn Lennqvist; Cecilia Fagerström; Cornelia M Witthöft
Journal:  Anal Bioanal Chem       Date:  2021-07-13       Impact factor: 4.142