Literature DB >> 29414002

Study of the use of axial viewed inductively coupled plasma atomic emission spectrometry with ultrasonic nebulization for the determination of select elemental impurities in oral drug products.

James Menoutis1, Angela Parisi2, Natasha Verma2.   

Abstract

In efforts to control the potential presence of heavy metals in pharmaceuticals, the United States Pharmacopeia (USP) and International Conference on Harmonization (ICH) have put forth new requirements and guidelines for their control. The new requirements and guidelines establish specific daily exposures (PDE) for 24 heavy metals/elemental impurities (EI) based upon their toxicological properties. USP General Chapter 〈233〉 provides a general reference procedure for preparing pharmaceutical samples for analysis employing microwave assisted digestion (MWAD). It also provides two Compendial Procedures, Procedure 1 employing ICP-AES, and Procedure 2 employing ICP-MS. Given the extremely low detection limits afforded by ICP-MS, much work has been done in developing and evaluating analytical methods to support the analysis of elemental impurities in finished pharmaceutical products, active pharmaceutical ingredients, and excipients by this analytical technique. In this study, we have evaluated the use of axial ICP-AES. This employs ultrasonic nebulization (UN) for the determination of Class 1 and 2 EI, instead of traditional pneumatic nebulization. The study also employed closed vessel MWAD to prepare samples for analysis. Limits of quantitation were element specific and significantly lower than the PDEs for oral drugs. Spike recoveries for the elements studied ranged between 89.3% and 109.25%, except for Os, which was subject to OsO4 formation during MWAD. The use of axial ICP-AES UN provides an alternative to ICP-MS in the analysis of EI requiring low detection limits.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Elemental impurities; ICH Q3D; ICP-AES; Inductively coupled plasma atomic emission spectroscopy; USP〈233〉; Ultrasonic nebulization

Mesh:

Substances:

Year:  2018        PMID: 29414002     DOI: 10.1016/j.jpba.2018.01.008

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  1 in total

1.  Development of a pH-induced dispersive solid-phase extraction method using folic acid combined with dispersive liquid-liquid microextraction: application in the extraction of Cu(II) and Pb(II) ions from water and fruit juice samples.

Authors:  Saeed Mohammad Sorouraddin; Kosar Parvizzad; Mir Ali Farajzadeh
Journal:  Anal Sci       Date:  2022-10-13       Impact factor: 1.967

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.