BACKGROUND: Sentinel lymph-node scintigraphy is a useful method for accurate staging of different tumors and a helpful tool in personalized therapy for oncological patients. The radiation exposure for surgical staff has been a concern since the sentinel lymph-node detection method was developed.
OBJECTIVE: The objective of the study was to determine and quantify the exposure to radiation of the non-dominant index for the surgeon performing sentinel lymph-node removal and to determine, if there is an irradiation risk imposed during the surgical procedure.
METHOD: We performed a study over a period of one year, where we evaluated the exposure of surgeon's non-dominant index during 196 sentinel lymph-node removal procedures. The pharmaceutical was administrated via subcutaneous injection in four peritumoral or perilesional injection sites. The equipment we used consisted of EuroProbe3 for sentinel lymph-node detection and ring TLD dosimeter placed on the surgeon's non-dominant index.
RESULTS: The clinical distribution was: 104 melanomas, 84 breast carcinomas, 6 vulvar carcinomas and 2 penial carcinomas. The administered activity showed an average of 39.55 MBq (SD ± 1.96) Tc-99m nanoalbumin compound. The non-dominant index exposure ranged between 0.10 mSv and 0.13 mSv/month with a cumulative dose of 1.31 mSv/year, thus 6.69 µSv per procedure.
CONCLUSION: The surgeon received a minimal dose for the non-dominant index. The values we recorded did not pose any additional concerns or restrictions, the exposure being under the limits and constraints established by regulations, close to the detectability limit of the dosimeter. The procedure is safe in terms of radiation protection, respecting the limitation and optimization principles. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

Entities:  

Keywords:  Sentinel lymph-node; Tc-99m nanocolloids; gammazzm321990probe.; limitation; non-dominant index exposure; radiation protection

Mesh:

Substances:

Year:  2018        PMID: 29412126     DOI: 10.2174/1874471011666180206165744

Source DB:  PubMed          Journal:  Curr Radiopharm        ISSN: 1874-4710


  1 in total

1.  Evaluation of Radiation Exposure During Sentinel Lymph Node Biopsy in Breast Cancer: A Retrospective Study.

Authors:  Rajaram Burrah; Karen James; Shabbir Poonawala
Journal:  World J Surg       Date:  2019-09       Impact factor: 3.352

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.