OBJECTIVE: The objective or our study was to assess the incidence rate and clinical characteristics of allergiclike reactions in patients who received both nonionic iodinated contrast medium (ICM) and gadolinium-based contrast medium (GBCM). MATERIALS AND METHODS: Acute allergiclike reactions in patients who received both ICM and GBCM to nonionic ICM or GBCM injections during a 5-year period were analyzed. Allergy preparation was not administered when patients received a different type of contrast material. Acute allergiclike reactions to both ICM and GBCM were evaluated. RESULTS: Of 302,858 contrast injections (155,234 ICM and 147,624 GBCM) during a 5-year period, 1006 (752 ICM and 254 GBCM) acute allergiclike contrast reactions were reported. The overall rate of reaction to ICM was 0.48% (95% CI, 0.45-0.52%), and the overall rate of reaction to GBCM was 0.17% (95% CI, 0.15-0.19%). A total of 19,237 patients received at least one ICM injection and one GBCM injection, with a total of 56,310 injections (19,237 initial injections and 37,073 subsequent injections). Nine patients had reactions to both ICM and GBCM with the primary reaction rate of 9/19,237 (incidence rate, 0.047%; 95% CI, 0.044-0.050%), and the secondary reaction rate of 9/37,073 (incidence rate, 0.024%; 95% CI, 0.023-0.026%). All secondary reactions in patients who had a reaction to both ICM and GBCM were mild. None of the patients required medication for the treatment of the secondary reaction. CONCLUSION: An allergiclike reaction to both nonionic ICM and GBCM was an extremely rare event that presented as a mild acute reaction without significant clinical consequences despite the fact that an allergy preparation was not administered.
OBJECTIVE: The objective or our study was to assess the incidence rate and clinical characteristics of allergiclike reactions in patients who received both nonionic iodinated contrast medium (ICM) and gadolinium-based contrast medium (GBCM). MATERIALS AND METHODS: Acute allergiclike reactions in patients who received both ICM and GBCM to nonionic ICM or GBCM injections during a 5-year period were analyzed. Allergy preparation was not administered when patients received a different type of contrast material. Acute allergiclike reactions to both ICM and GBCM were evaluated. RESULTS: Of 302,858 contrast injections (155,234 ICM and 147,624 GBCM) during a 5-year period, 1006 (752 ICM and 254 GBCM) acute allergiclike contrast reactions were reported. The overall rate of reaction to ICM was 0.48% (95% CI, 0.45-0.52%), and the overall rate of reaction to GBCM was 0.17% (95% CI, 0.15-0.19%). A total of 19,237 patients received at least one ICM injection and one GBCM injection, with a total of 56,310 injections (19,237 initial injections and 37,073 subsequent injections). Nine patients had reactions to both ICM and GBCM with the primary reaction rate of 9/19,237 (incidence rate, 0.047%; 95% CI, 0.044-0.050%), and the secondary reaction rate of 9/37,073 (incidence rate, 0.024%; 95% CI, 0.023-0.026%). All secondary reactions in patients who had a reaction to both ICM and GBCM were mild. None of the patients required medication for the treatment of the secondary reaction. CONCLUSION: An allergiclike reaction to both nonionic ICM and GBCM was an extremely rare event that presented as a mild acute reaction without significant clinical consequences despite the fact that an allergy preparation was not administered.
Authors: Natalia Sauer; Wojciech Szlasa; Laura Jonderko; Krystyna Głowacka; Katarzyna Karłowicz-Bodalska; Anna Wiela-Hojeńska Journal: Int J Environ Res Public Health Date: 2022-06-09 Impact factor: 4.614
Authors: D A Tonetti; S M Desai; A Morrison; B A Gross; T G Jovin; B T Jankowitz; A P Jadhav Journal: AJNR Am J Neuroradiol Date: 2020-08-06 Impact factor: 3.825
Authors: Wendie A Berg; Elizabeth A Rafferty; Sarah M Friedewald; Carrie B Hruska; Habib Rahbar Journal: AJR Am J Roentgenol Date: 2020-12-23 Impact factor: 3.959
Authors: Jan Endrikat; Julia Chernova; Christoph Gerlinger; Marcin Pracz; Philipp Lengsfeld; Aasia Bhatti; Alexander Michel Journal: Invest Radiol Date: 2022-05-01 Impact factor: 6.016