| Literature DB >> 29410555 |
Ju-Young Heo1, Hwa-Kyung Shin2.
Abstract
[Purpose] The purpose of this study was to translate the Trunk Control Measurement Scale into a Korean version and to analyze the intra- and inter-rater reliability.Entities:
Keywords: Cerebral palsy; Reliability; Trunk control measurement scale
Year: 2018 PMID: 29410555 PMCID: PMC5788764 DOI: 10.1589/jpts.30.1
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Test-retest reliability on sublevel of K-TCMS
| Sublevel | Tester 1 | Tester 2 | Tester 3 | Tester 4 |
|---|---|---|---|---|
| Static sitting balance | 0.972a (0.916–0.991)b,* | 0.999 (0.998–1.000) | 0.998 (0.994–0.999)* | 0.998 (0.995–0.999)* |
| Dynamic sitting balance | 0.979 (0.936–0.993)* | 0.999 (0.998–1.000)* | 0.995 (0.984–0.998)* | 0.986 (0.960–0.995)* |
| Dynamic reaching | 0.941 (0.826–0.980)* | 1.000* | 0.996 (0.987–0.998)* | 0.997 (0.991–0.999)* |
aICC: Intraclass correlation coefficient, bCI: Confidence interval. Value are Mean ± Standard Deviation. *p<0.05.
Inter-rater reliability on sublevel of K-TCMS
| TCMS | mean ± SD | ICCa | 95% CIb | p | |
|---|---|---|---|---|---|
| Static sitting balance | |||||
| Tester 1 | 16.30 ± 5.00 | 0.98 | 0.955–0.992 | 0.00 | |
| Tester 2 | 16.57 ± 5.05 | ||||
| Tester 3 | 15.50 ± 4.58 | ||||
| Tester 4 | 16.60 ± 4.50 | ||||
| Dynamic sitting balance | |||||
| Tester 1 | 16.57 ± 5.94 | 0.95 | 0.885–0.982 | 0.00 | |
| Tester 2 | 15.20 ± 6.09 | ||||
| Tester 3 | 13.83 ± 7.59 | ||||
| Tester 4 | 17.13 ± 7.21 | ||||
| Dynamic reaching | |||||
| Tester 1 | 8.63 ± 1.99 | 0.91 | 0.811–0.967 | 0.00 | |
| Tester 2 | 8.93 ± 1.94 | ||||
| Tester 3 | 8.90 ± 1.93 | ||||
| Tester 4 | 7.97 ± 2.36 | ||||
aICC: Intraclass correlation coefficient, bCI: Confidence interval. p<0.05.