Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture.

Teik Wei Diong1, Nor Hazla Mohamed Haflah1, Abdul Yazid Mohd Kassim1, Sharifah Majedah Idrus Al Habshi2, Mohd Hassan Shukur1.   

Abstract

BACKGROUND: The use of volar locking plate in distal radius fracture can lead to extensor tendon rupture due to dorsal screw penetration. The aim of our study was to investigate the occurrence of dorsal and intra-articular screw penetration using CT scan after volar distal radius osteosynthesis for distal radius fractures.
METHODS: Thirty patients who underwent distal volar locking plate for distal radius fracture were included in a retrospective study. In all 30 patients no dorsal and intra-articular screw penetration were detected on standard AP and lateral views of a plain radiograph. CT scan of the operated wrist was performed to determine the number of intra-articular and dorsal screw penetrations. Clinical examination was performed to determine the wrist functions in comparison to the normal wrist.
RESULTS: Nineteen wrists were noted to have screw penetration either dorsally or intraarticularly. The highest incidence is in the 2nd extensor compartment where 13 screws had penetrated with a mean of 2.46 mm. Six screws penetrated into the distal radial ulnar joint and five screws into the wrist joint with a mean of 2.83 mm and 2.6 mm, respectively. However, there was no incidence of tendon irritation or rupture.
CONCLUSIONS: This study demonstrated a high incidence of dorsal and intra-articular screw penetration detected by CT scan which was not apparent in plain radiograph. We recommend that surgeons adhere to the principle of only near cortex fixation and downsizing the locking screw length by 2 mm.

Entities:  

Keywords:  CT scans; Distal radius; screw penetration; volar locking plate

Mesh:

Year:  2018        PMID: 29409409     DOI: 10.1142/S2424835518500030

Source DB:  PubMed          Journal:  J Hand Surg Asian Pac Vol


  2 in total

1.  Volar Locking Plate Fixation for Distal Radius Fractures by Intraoperative Computed Tomographic-Guided Navigation.

Authors:  Akira Kawabata; Yusuke Sogabe; Yukiko Morimoto; Kiyohito Takamatsu
Journal:  J Hand Surg Glob Online       Date:  2020-09-08

2.  3D virtual pre-operative planning may reduce the incidence of dorsal screw penetration in volar plating of intra-articular distal radius fractures.

Authors:  Jasper Prijs; Bram Schoolmeesters; Denise Eygendaal; Jean-Paul P M de Vries; Paul C Jutte; Job N Doornberg; Ruurd L Jaarsma; Frank F A IJpma
Journal:  Eur J Trauma Emerg Surg       Date:  2021-10-08       Impact factor: 2.374