M J Welck1, D Singh2, N Cullen2, A Goldberg2. 1. Foot and Ankle Unit, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex HA7 4LP, United Kingdom. Electronic address: matthewwelck@doctors.org.uk. 2. Foot and Ankle Unit, Royal National Orthopaedic Hospital, Brockley Hill, Stanmore, Middlesex HA7 4LP, United Kingdom.
Abstract
BACKGROUND: Little is understood about the role that relative sesamoid displacement and chondral wear have on outcome after hallux valgus (HV) surgery. All existing methods to evaluate relative sesamoid displacement have limitations and furthermore, there have been no radiographic studies evaluating metatarso-sesamoid joint wear. Standing CT scan circumvents many of the existing problems in evaluation of relative sesamoid displacement, and also enables the first radiographic study assessing metatarso-sesamoid joint wear. METHODS: Fifty feet (in 43 patients) with symptomatic HV (Group A) were compared with a control group of 50 feet (50 patients) (Group B). All images were standardised to enable reproducible measurements. The hallux valgus angle, Intermetatarsal angle, sesamoid rotation angle, sesamoid position and metatarso-sesamoid joint space were measured in all patients. RESULTS: The intra and inter-observer reliability correlation showed that the standing CT assessment of sesamoid position (1.000), rotation (0.991) and metatarso-sesamoid joint space (0.960) were highly reproducible. There was a highly significant difference (p<0.0001) in sesamoid position, sesamoid rotation and metatarso-sesamoid joint space between Group A and Group B. CONCLUSIONS: Standing CT has been shown to be a reproducible and accurate method of assessing the relative sesamoid displacement and metatarso-sesamoid joint space narrowing. The results have been used to propose a novel standing CT based classification of hallucal sesamoids, considering the degree of displacement and wear. This classification may ultimately facilitate research to provide new insight into the effect relative sesamoid displacement and chondral wear have on outcomes from hallux valgus surgery. Crown
BACKGROUND: Little is understood about the role that relative sesamoid displacement and chondral wear have on outcome after hallux valgus (HV) surgery. All existing methods to evaluate relative sesamoid displacement have limitations and furthermore, there have been no radiographic studies evaluating metatarso-sesamoid joint wear. Standing CT scan circumvents many of the existing problems in evaluation of relative sesamoid displacement, and also enables the first radiographic study assessing metatarso-sesamoid joint wear. METHODS: Fifty feet (in 43 patients) with symptomatic HV (Group A) were compared with a control group of 50 feet (50 patients) (Group B). All images were standardised to enable reproducible measurements. The hallux valgus angle, Intermetatarsal angle, sesamoid rotation angle, sesamoid position and metatarso-sesamoid joint space were measured in all patients. RESULTS: The intra and inter-observer reliability correlation showed that the standing CT assessment of sesamoid position (1.000), rotation (0.991) and metatarso-sesamoid joint space (0.960) were highly reproducible. There was a highly significant difference (p<0.0001) in sesamoid position, sesamoid rotation and metatarso-sesamoid joint space between Group A and Group B. CONCLUSIONS: Standing CT has been shown to be a reproducible and accurate method of assessing the relative sesamoid displacement and metatarso-sesamoid joint space narrowing. The results have been used to propose a novel standing CT based classification of hallucal sesamoids, considering the degree of displacement and wear. This classification may ultimately facilitate research to provide new insight into the effect relative sesamoid displacement and chondral wear have on outcomes from hallux valgus surgery. Crown
Authors: Nacime Salomão Barbachan Mansur; Matthieu Lalevee; Eli Schmidt; Kevin Dibbern; Pablo Wagner; Emilio Wagner; Caio Augusto de Souza Nery; Cesar de Cesar Netto Journal: Int Orthop Date: 2021-08-12 Impact factor: 3.075
Authors: Alexandre Leme Godoy-Santos; Alessio Bernasconi; Marcelo Bordalo-Rodrigues; François Lintz; Carlos Felipe Teixeira Lôbo; Cesar de Cesar Netto Journal: Radiol Bras Date: 2021 May-Jun