Literature DB >> 29408767

The Woven EndoBridge (WEB) for endovascular therapy of intracranial aneurysms: Update of a systematic review with meta-analysis.

Noam Tau1, Udi Sadeh-Gonik2, Gilles Aulagner3, Francis Turjman4, Benjamin Gory5, Xavier Armoiry6.   

Abstract

OBJECTIVES: Endovascular treatment of wide-neck intracranial aneurysms (IAs) is challenging, especially in bifurcation location. The intra-saccular flow-disruptor Woven EndoBridge (WEB) offers a new concept of endovascular therapy for wide-neck IAs. We performed an update of a systematic review aimed to report the feasibility, effectiveness and safety of WEB device therapy. PATIENTS AND METHODS: A systematic review was conducted using several electronic databases (including PUBMED and EMBASE), searching for studies published between October 2015 and December 2017 (those published between January 2010 and September 2015 were included in our initial systematic review). Outcomes were: success of implantation, peri-procedural complications, mortality, and adequate occlusion (complete occlusion or neck remnant).
RESULTS: In total (initial review + update), 12 uncontrolled case-series studies were included, reporting outcomes for 940 patients (68.6% female; mean age, 57 years) harboring 962 IAs. Most IAs were wide-neck bifurcation aneurysms (75%-100%), mainly at middle cerebral artery (37%) and anterior communicating artery (24.6%). Feasibility was 97% (95% confidence interval [CI], 95%-99%), and 9% (95%CI, 5%-14%) of cases required additional treatment. There were 14% (95%CI, 9%-19%) peri-procedural complications. After a median clinical follow-up of 7 months, mortality was 5% (95%CI, 1%-10%) and was higher in series with larger proportions of ruptured IAs. At last angiographic follow-up (median, 7 months; range, 3-27.9 months), adequate occlusion rate was 81% (95%CI, 73%-88%).
CONCLUSION: Although WEB showed high rates of adequate aneurysm occlusion at mid-term, procedure-related complications and mortality rates were not negligible. Future studies should compare the WEB device with other treatment options.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Embolization; Endovascular treatment; Intracranial aneurysm; Woven EndoBridge

Mesh:

Year:  2018        PMID: 29408767     DOI: 10.1016/j.clineuro.2018.01.025

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  13 in total

1.  The Woven EndoBridge device for ruptured intracranial aneurysms: international multicenter experience and updated meta-analysis.

Authors:  Pablo Harker; Robert W Regenhardt; Naif M Alotaibi; Justin Vranic; Faith C Robertson; Adam A Dmytriw; Jerry C Ku; Matthew Koch; Christopher J Stapleton; Thabele M Leslie-Mazwi; Nelson Serna; Boris Pabon; Juan A Mejia; Aman B Patel
Journal:  Neuroradiology       Date:  2021-05-25       Impact factor: 2.804

2.  Two-Center Experience in the Endovascular Treatment of Intracranial Aneurysms Using the Woven EndoBridge 17 Device Including Midterm Follow-Up Results: A Retrospective Analysis.

Authors:  C Maurer; I König; A Berlis; W Weber; S Fischer
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

3.  Treatment of Wide-Neck Intracranial Aneurysms with the Woven EndoBridge Device Associated with Stenting: A Single-Center Experience.

Authors:  F Cagnazzo; R Ahmed; C Dargazanli; P-H Lefevre; G Gascou; I Derraz; S A Kalmanovich; C Riquelme; A Bonafe; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

4.  A systematic review and meta-analysis of Woven EndoBridge single layer for treatment of intracranial aneurysms.

Authors:  Sbt van Rooij; M E Sprengers; J P Peluso; J Daams; D Verbaan; W J van Rooij; C B Majoie
Journal:  Interv Neuroradiol       Date:  2020-02-06       Impact factor: 1.610

5.  The RISE trial: A Randomized Trial on Intra-Saccular Endobridge devices.

Authors:  Jean Raymond; Anne-Christine Januel; Daniela Iancu; Daniel Roy; Alain Weill; Andrew Carlson; Tim E Darsaut
Journal:  Interv Neuroradiol       Date:  2019-11-05       Impact factor: 1.610

6.  Low-Profile Intra-Aneurysmal Flow Disruptor WEB 17 versus WEB Predecessor Systems for Treatment of Small Intracranial Aneurysms: Comparative Analysis of Procedural Safety and Feasibility.

Authors:  L Goertz; T Liebig; E Siebert; M Herzberg; L Pennig; M Schlamann; J Borggrefe; B Krischek; F Dorn; C Kabbasch
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-05       Impact factor: 3.825

7.  Trends of Expanding Indications of Woven EndoBridge Devices for the Treatment of Intracranial Aneurysms: A Systematic Review and Meta-analysis.

Authors:  Ki Baek Lee; Chong Hyun Suh; Yunsun Song; Boseong Kwon; Mi Hyeon Kim; Jong-Tae Yoon; Deok Hee Lee
Journal:  Clin Neuroradiol       Date:  2022-08-29       Impact factor: 3.156

8.  Volume-based sizing of the Woven EndoBridge (WEB) device: A preliminary assessment of a novel method for device size selection.

Authors:  Kevin A Shah; Timothy G White; Ina Teron; Thomas Link; Amir R Dehdashti; Jeffrey M Katz; Henry H Woo
Journal:  Interv Neuroradiol       Date:  2021-01-21       Impact factor: 1.764

Review 9.  The Woven Endobridge as a treatment for acutely ruptured aneurysms: A review of the literature.

Authors:  William Crinnion; Pervinder Bhogal; Hegoda Levansri Dilrukshan Makalanda; Ken Wong; Adam Arthur; Christophe Cognard; Hans Henkes; Dave Fiorella; Laurent Pierot
Journal:  Interv Neuroradiol       Date:  2021-01-28       Impact factor: 1.764

10.  Treatment of Acutely Ruptured Cerebral Aneurysms With the Woven EndoBridge Device: Experience Post-FDA Approval.

Authors:  Fadi Al Saiegh; David Hasan; Nikolaos Mouchtouris; Mario Zanaty; Ahmad Sweid; Omaditya Khanna; Nohra Chalouhi; Ritam Ghosh; Stavropoula Tjoumakaris; M Reid Gooch; Robert Rosenwasser; Pascal Jabbour
Journal:  Neurosurgery       Date:  2020-07-01       Impact factor: 4.654