Literature DB >> 29408710

Delayed release of chemokine CCL25 with bioresorbable microparticles for mobilization of human mesenchymal stem cells.

Kristin Fröhlich1, David Hartzke2, Franziska Schmidt3, Jan Eucker4, Aleksander Gurlo3, Michael Sittinger2, Jochen Ringe5.   

Abstract

Chemokines are guiding cues for directional trafficking of mesenchymal stem cells (MSC) upon injury and local chemokine delivery at injury sites is an up-to-date strategy to potentiate and prolong recruitment of MSC. In this study we present the chemokine CCL25, also referred to as thymus-expressed chemokine, to mobilize human MSC along positive but not along negative gradients. We hence proceeded to design a biodegradable and injectable release device for CCL25 on the basis of poly(lactic-co-glycolic acid) (PLGA). The conducted studies had the objective to optimize PLGA microparticle fabrication by varying selected formulation parameters, such as polymer type, microparticle size and interior phase composition. We found that microparticles of DV,50∼75 µm and fabricated using end-capped polymers, BSA as carrier protein and vortex mixing to produce the primary emulsion yielded high chemokine loading and delayed CCL25 release. To determine bioactivity, we investigated CCL25 released during the microparticle erosion phase and showed that deacidification of the release medium was required to induce significant MSC mobilization. The designed PLGA microparticles represent an effective and convenient off-the-shelf delivery tool for the delayed release of CCL25. However, continuative in vivo proof-of-concept studies are required to demonstrate enhanced recruitment of MSC and/or therapeutical effects in response to CCL25 release microparticles. STATEMENT OF SIGNIFICANCE: With the discovery of chemokines, particularly CXCL12, as stimulators of stem cell migration, the development of devices that release CXCL12 has proceeded quickly in the last few years. In this manuscript we introduce CCL25 as chemokine to induce mobilization of human MSC. This study proceeds to demonstrate how selection of key formulation parameters of CCL25 loading into PLGA microparticles exerts considerable influence on CCL25 release. This is important for a broad range of efforts in in situ tissue engineering where the candidate chemokine and the delivery device need to be selected carefully. The use of such a cell-free CCL25 release device may provide a new therapeutic option in regenerative medicine.
Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  CCL25; Chemokines; In situ tissue engineering; Mesenchymal stem cells; PLGA microparticles

Mesh:

Substances:

Year:  2018        PMID: 29408710     DOI: 10.1016/j.actbio.2018.01.036

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  1 in total

1.  Therapies with CCL25 require controlled release via microparticles to avoid strong inflammatory reactions.

Authors:  J Spinnen; K Fröhlich; N Sinner; M Stolk; J Ringe; L Shopperly; M Sittinger; T Dehne; M Seifert
Journal:  J Nanobiotechnology       Date:  2021-03-25       Impact factor: 10.435

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.