Literature DB >> 2940852

Two-dimensional echocardiography during percutaneous transluminal coronary angioplasty.

C A Visser, G K David, G Kan, K H Romijn, R S Meltzer, J J Koolen, A J Dunning.   

Abstract

In order to study myocardial and clinical events during transient coronary occlusion in humans, two-dimensional echocardiography was continuously performed in 15 patients undergoing 49 balloon inflations during percutaneous transluminal coronary angioplasty (PTCA). Transient segmental asynergy developed in all patients 8 +/- 3 seconds after balloon inflation and returned to baseline 19 +/- 8 seconds after balloon deflation. Segmental dyskinesis was seen in only 8 of 11 patients undergoing PTCA of the left anterior descending artery (LAD). A wall motion score, based on degree of asynergy of 13 segments of the left ventricle, was significantly higher during LAD than during right coronary artery inflation (7.9 +/- 1.3 vs 4.0 +/- 1.4, p less than 0.01). Left ventricular size index increased significantly during balloon inflation, from 179 +/- 9 to 196 +/- 10 mm (p less than 0.01). Four patients developed transient ST segment changes in the extremity leads of the ECG and five patients had angina pectoris. The very first sign of ischemia in three patients, who developed all of these symptoms together, was consistently asynergy, followed by ECG changes, and last, angina pectoris. Thus during PTCA, transient asynergy and left ventricular dilatation develop, which are often clinically silent.

Entities:  

Mesh:

Year:  1986        PMID: 2940852     DOI: 10.1016/0002-8703(86)90003-7

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  6 in total

1.  Reperfusion Injury: Does It Exist and Does It Have Clinical Relevance?

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1997-01       Impact factor: 2.300

2.  Assessment of left ventricular performance during percutaneous transluminal coronary angioplasty: a study by intravenous digital subtraction ventriculography.

Authors:  M S Norell; J P Lyons; A H Gershlick; J E Gardener; M T Rothman; C A Layton; R Balcon
Journal:  Br Heart J       Date:  1988-04

3.  Changes in myocardial echo amplitude during reversible ischaemia in humans.

Authors:  D A Lythall; D G Gibson; S S Kushwaha; M S Norell; A G Mitchell; C J Ilsley
Journal:  Br Heart J       Date:  1992-05

Review 4.  Left ventricular dysfunction due to stunning and hibernation in patients.

Authors:  R Ferrari; G La Canna; R Giubbini; E Milan; C Ceconi; F de Giuli; P Berra; O Alfieri; O Visioli
Journal:  Cardiovasc Drugs Ther       Date:  1994-05       Impact factor: 3.727

Review 5.  Myocardial stunning in man.

Authors:  Edward Barnes; Masood A Khan
Journal:  Heart Fail Rev       Date:  2003-04       Impact factor: 4.214

6.  Rotational ablation of discrete lesions in the coronary arteries is safe. A nonrandomized comparison with percutaneous transluminal coronary angioplasty.

Authors:  J Cheirif; R Wray; J Heibig; S Harris; R Staudacher; M Bucay; N Zacca
Journal:  Tex Heart Inst J       Date:  1995
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.