Literature DB >> 29403803

Electrochemical study and application on rutin at chitosan/graphene films modified glassy carbon electrode.

Jing An1, Ying-Yan Bi1, Chun-Xia Yang1, Fang-Di Hu1, Chun-Ming Wang2.   

Abstract

Graphene (G) was dispersed into 0.5% chitosan (Chit) solution, then the composite films were coated on glassy carbon electrode (GCE), the electrochemical behavior of rutin on a Chit/G modified GCE was investigated and the electrochemical parameters of rutin were calculated. Rutin effectively accumulated on the Chit/G/GCE and caused a pair of redox peaks at around 408 mV and 482 mV (vs. SCE) in 0.1 M phosphate buffer solution (pH 4.0). Under optimized conditions, the anodic peak current was linear to the rutin concentration in the range of 5×10-7-1.04×10-5 M. The regression equation was: y=9.9219x-0.0025, r= 0.9958. The proposed method was successfully used for the determination of rutin content in tablet samples with satisfactory results.

Entities:  

Keywords:  Chitosan/graphene films; Differential pulse voltammetry; Electrochemical; Rutin

Year:  2012        PMID: 29403803      PMCID: PMC5760938          DOI: 10.1016/j.jpha.2012.09.003

Source DB:  PubMed          Journal:  J Pharm Anal        ISSN: 2214-0883


Introduction

Rutin (Fig. 1), a kind of the most abundant bioactive flavonoid, is the main active ingredient in Sophora japonica L.
Fig. 1

Chemical structure of rutin.

Chemical structure of rutin. Known as vitamin P, rutin has a broad range of physiological activities such as anti-oxidant [1], antiviral [2], anti-inflammatory [3], [4], and anti-depression [5], and it has potential to treat diabetes [6] and hypertension [7]. Some analytical methods, including high performance liquid chromatography [8], [9], capillary electrophoresis [10], [11], [12], spectrophotometry [13], have been employed for the determination of rutin. However, some of these methods are time-consuming, expensive or need complicated pre-treatment, which hamper their further application. Compared with these methods, electrochemical determination shows advantages of satisfactory reliability, fast response, inexpensive instrument, low energy consumption, simple operation, time saving, high sensitivity and selectivity, especially in situ determination. In recent years, with the development of nanoscience and nanotechnology, many nanomaterial-based electrodes, which can dramatically enhance the signal intensity of electrochemical sensor and lead to ultrasensitive determination, have been applied for the electrochemical determination of rutin [14], [15]. The electrochemical measurement has also been applied to analyze rutin, whose construction contains electrochemical active group [16], [17], [18], [19]. However, to the best of our knowledge, it was still a challenge for the fabrication of novel electrochemical sensors using graphene to achieve sensitive, fast and facile detection of rutin. Graphene (G), owing to its unique two-dimensional nanostructure and excellent electrical conductivity, has attracted enormous attention following the discovery of nanotube. As the thinnest carbon material until now, graphene has exhibited potential applications in electrode modifying materials [20], sensors [21], and drug carrier [22], [23]. Chitosan (Chit), a natural polymer, has many admirable properties such as non-toxicity, biodegradability, and good compatibility. Bringing with quantity of amino and hydroxyl active group, chitosan has been widely used due to its absorption enrichment to some certain organic composites and chelation of metal ion and silver nano-particle has been widely employed for the modification of electrode because of its high surface area and outstanding electrical conductivity. In this paper, a Chit/G/GCE, integrating the absorption enrichment of Chit, excellent electrical conductivity of graphene and high surface area of nano-metal, was fabricated and the electrochemical behavior of rutin on this Chit/G/GCE was investigated. The result demonstrated that both the metal particle and Chit/G contributed to the sensitive detection of rutin to a certain degree. Compared with the existing electrochemical methods, this research has some innovative results in the biocompatibility of graphene and the selectivity and sensitivity of rutin analysis. Furthermore, this novel method was successfully used for the determination of rutin content in samples with satisfactory results, providing a basis for its application to the measurement of active substance in vivo.

Materials and methods

Apparatus and reagents

CHI1220 electrochemical workstation (Shanghai Shenhua Instrument Co., Ltd., Shanghai, China) was employed for all the voltammetric measurement, and 7821 magnetic stirring apparatus was used to prepare all the solutions. A conventional three-electrode system was used, including Chit/G modified GCE as working electrode, a saturated calomel electrode as reference electrode and a platinum wire electrode as auxiliary electrode. Chit (deacetylation degree >90%, Sinopharm Chemical Reagent Co., Ltd.), graphite (AR, Shanghai Chemical Reagent Co., Ltd.), rutin (100080, National Institute of China for the Control of Pharmaceutical and Biological Products.), hydrogen peroxide (10–30 nm, Bill Technology Co., Ltd. Shenzhen), potassium permanganate (AR, Shanghai Hui Shisheng Reagent Co., Ltd.), sodium nitrate (AR), sodium hydroxide (AR), sodium dihydrogen phosphate (AR), disodium hydrogen phosphate (AR) and redistilled water were used. Phosphate buffer solution was prepared by NaH2PO4Na2HPO4 and pH value was adjusted by NaOH and H3PO4. All of the experiments were processed at room temperature (∼20 °C).

Preparation of graphene

Natural graphite powders were oxidized to graphite oxide using a modified Hummers method. In a typical synthesis process, graphite powder and sodium nitrate were put into concentrated H2SO4 (in an ice bath). Afterward, KMnO4 was gradually added. The mixture was then transferred to room temperature and stirred for about 5 h, forming a thick paste. Subsequently, de-ionized water and 30% H2O2 were added to reduce the residual KMnO4. The solution was then treated by ultrasonication for 5 h and washed with de-ionized water until the pH was 7 and dried at 65 °C under vacuum to obtain graphene oxide (GO) solid. G was obtained by the reduction of GO using hydrazine hydrate as a reducing agent. And then, the mixture was washed several times until the pH was 7 and dried under vacuum.

Fabrication of Chit/G/GCE

Pretreatment of bare GCE

Before the start of the electrochemical experiments and modification procedures, the GCE was burnished on the metallographic sandpaper, then polished to a mirror-like surface with 0.05 μm α-alumina slurries and finally ultrasonicated for 3 min in nitric acid (1:1), ethanol and redistilled water successively. Finally, the surface of electrode was dried by nitrogen.

Fabrication of electrochemical sensor

Chit was first dissolved in acetic acid (1 mL in 100 mL). This was stirred for 2 h to generate chitosan solution (0.5 mL in 100 mL, adjusted pH=5 by 0.1 M NaOH). Subsequently, 1.5 mg G was cast into the solution (1.0 mL), followed by ultrasonication for 2 h. Then 4 μL of the as-prepared Chit/G composite (1.5 M) was dropped on the pretreated GCE using micropipette and dried in a desiccator for 2 h at room temperature. Meanwhile, 100 nanoAg was cast into the solution of Chit/G composite and the G/Chit/nanoAg was obtained after 2 h ultrasonic dispersion. Finally, this solution was dropped on the GCE using the same method. And the obtained electrodes were placed at 4 °C.

Cyclic voltammetry (CV)

Unless otherwise stated, 0.1 M PBS (pH 4.0) was used as the supporting electrolyte. A certain volume of rutin standard solution and PBS was added into an electrochemical cell. The G/Chit/GCE was used as working electrode, a platinum wire as counter electrode and a saturated calomel electrode as reference electrode completing the cell assembly. Cyclic voltammograms were scanned from 0.2 to 0.8 V with the rate of 100 mV/s. The electrodes were modified again after each scan.

Differential pulse voltammetry (DPV)

Before the electrodes were used to analyze samples, a steady G volt–ampere characteristic (from −0. 2 to 0.8 V) should be achieved in a PBS (pH=4). A certain volume of rutin standard solution and PBS (10 mL totally) was added into an electrochemical cell. DPV was scanned from −0.2 to 0.8 V and the height of current peaks was recorded.

Results and discussion

Characteristics of graphene and the mixture of G and Chit

Fig. 2(A) shows the scanning electron micrograph (SEM) image of graphene nanosheets, which exhibited a significant difference with GCE. Transmission electron microscope (TEM) can effectively prove the morphologies of the mixture of G and Chit. Fig. 2(B) shows the TEM image of Chit/G composite, clearly clarifying the crumpled and wrinkled flake-like structure.
Fig. 2

(A) SEM image of G and (B) TEM image of G/Chit film.

(A) SEM image of G and (B) TEM image of G/Chit film.

Electrochemical response of rutin on G/Chit/GCE

The electrochemical behavior of rutin (1×10−5 M) on different electrodes (GCE, Chit/G/GCE, Chit/G/nanoAg/GCE and G/GCE) was studied by CV. As shown in Fig. 3, rutin showed redox current peaks at 0.408 V and 0.482 V. The heights of the redox peaks were in agreement with this order: I (GCE)GCE)GCE)GCE). The unique two-dimensional nanostructure of G could benefit to the electrical conductivity, which explains the increased peak currents and background. Furthermore, the redox peaks also rose after the presence of Chit. However, the addition of nanoAg resulted in an opposite effect. This phenomenon may be related to the complexing action between nanoAg and amino group of Chit, leading to fewer binding sites of rutin and Chit.
Fig. 3

CVs of bare GCE (a), G/GCE (b), Chit/G/nanoAg (c) and Chit/G/GCE (d) with 1×10−5 M rutin in 0.1 M PBS (pH 4.0) at 100 mV/s.

CVs of bare GCE (a), G/GCE (b), Chit/G/nanoAg (c) and Chit/G/GCE (d) with 1×10−5 M rutin in 0.1 M PBS (pH 4.0) at 100 mV/s.

Optimization of experimental conditions

Effect of pH

Fig. 4(A) displays the effect of different pH on the response of 1×10−5 M rutin. When the pH changed from 2.0 to 9.0 (by NaOH), the anodic peak in CV moved towards the negative direction and the current response decreased. There was a linear relationship between the anodic peak potential and the pH value as follows (Fig. 4(B)):
Fig. 4

(A) CVs of Chit/G modified GCE in 0.10 M PBS containing 1×10−5 M of rutin with pH values of 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0 at scan rate of 100 mV/s and (B) plot of equilibrate potentials vs. pH values.

(A) CVs of Chit/G modified GCE in 0.10 M PBS containing 1×10−5 M of rutin with pH values of 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0 at scan rate of 100 mV/s and (B) plot of equilibrate potentials vs. pH values. According to the slope of 57 mV/pH, it could be deduced that H+ participated in this reaction and the number of electrons and protons transferred was equal in the electrochemical reaction. When the pH was over 7.0, the anodic peak became very small and irreversible. These experimental phenomena were related to the proton involved in the electrochemical reaction. When pH exceeded 7.0, with the increase of negative ions, the electrostatic repulsion occurred between chitosan and rutin, leading to the reduction of current. Yang et al. [24] studied the electrochemical behavior of rutin on a Chit/G/GCE and the linear relationship between the anodic peak potential and pH was Epa=0.6838–0.056 pH (r=0.9984), whose rate of slope is similar to our own result. In the meantime, with regard to Faraday's law, they investigated the mechanism of this electrode reaction and deduced that the number of electrons and protons transferred was both two in this electrochemical action (Fig. 5).
Fig. 5

Mechanism of rutin redox processes.

Mechanism of rutin redox processes.

Effect of scan rate

The effect of scan rate on the electrochemical response of 1×10−5 M rutin is shown in Fig. 6(A). With the increase of scan rate, the redox peak currents increased simultaneously without significant change in peak potential. Both the cathodic and anodic peak currents increased linearly with the scan rate from 20 to 200 mV/s (Fig. 6(B)), indicating an adsorption-controlled process. The regression equation was
Fig. 6

(A) CVs of Chit/G modified GCE in 0.10 M PBS (pH 4.0) containing 1×10−5 M of rutin at scan rate of 20, 40, 60, 80, 100, 120, 160,180 and 200 mV/s and (B) plot of peak current vs. scan rate.

(A) CVs of Chit/G modified GCE in 0.10 M PBS (pH 4.0) containing 1×10−5 M of rutin at scan rate of 20, 40, 60, 80, 100, 120, 160,180 and 200 mV/s and (B) plot of peak current vs. scan rate.

Effect of the amount of modification

The effect of the amount of modification was also investigated in rutin solution. When the volume of Chit/G composite increased on the surface of electrode, the peak current increased first until it was up to 4 μL, and then decreased (Fig. 7), indicating that rutin cannot be fully enriched on the less modified electrodes, nonetheless, the peak current decreased on over modified electrodes because increased electron transfer path would affect the sensitivity of electrodes. Therefore, 4 μL was selected as the amount of modification.
Fig. 7

Plot of peak current vs. modified amount.

Plot of peak current vs. modified amount.

Effect of accumulation time

The effect of accumulation time on its reduction peak current was also investigated in 1×10−5 M rutin solution for the Chit/G/GCE. With the increase of accumulation time (1 , 3 , 5  and 7 min), the anodic peak current increased gradually. And the peak current reached the maximum after 7 min and then tended to be stable, indicating that 7 min was sufficient to reach the rutin saturation on the Chit/G/GCE. Therefore, 7 min was generally chosen as the accumulation time.

Calibration curve

Under optimal conditions, DPV was explored for the amperometric response of rutin at the proposed electrochemical sensor. Fig. 8(A) shows the typical DPV obtained at different concentrations of rutin. The peak currents had a good linear relationship with the rutin concentration in the range of 5×10−7–1.04×10−5 M, as shown in Fig. 8(B). The linear regression equation was
Fig. 8

(A) DPV of different concentrations of rutin (in the range of 5×10−7–1.04×10−5 M) and (B) concentration calibration curve of the DPV current response for rutin.

(A) DPV of different concentrations of rutin (in the range of 5×10−7–1.04×10−5 M) and (B) concentration calibration curve of the DPV current response for rutin.

Reproducibility and stability

Reproducibility and stability are two important characteristics for the modified electrode, which should be investigated. The reproducibility of the proposed electrochemical sensor was evaluated by the determination of ten samples of 1.0×10−6 M rutin solution using ten modified electrodes separately. The average peak current is 9.12 μA and the standard deviation (SD) was 4.7% which suggested acceptable reproducibility of the proposed electrochemical sensor (RSD=5.15%). Furthermore, the 1.0×10−6 M rutin solution was also measured by modified electrodes which were placed for 1 week at 4 °C. There were no significant changes in current.

Interference studies

The influence of some coexistent interference substances was examined in the presence of rutin solutions. The results showed that when the concentrations of ascorbic acid, glucose, uric acid, and glutamic acid were 50 times more than those of rutin, the concentrations of l-tryptophan, l-serine, l-histidine, and rhein were 100 times more, and no observable interference was observed in the determination of rutin according to the relative error <±5%. Furthermore, large quantity of sodium or potassium ions also do not interfere with the results. Therefore, the proposed method had excellent selectivity for rutin. However, some compounds, such as flavonoids and dopamine, whose peak potentials were very close to that of rutin, caused significant interferences. The recovery of this developed method was evaluated by the determination of six samples of rutin solution, which was prepared by ultrasound dissolving rutin tablets and whose concentration was controlled within detection limit. The content of rutin was detected via the peak current in 0.408 V. As shown in Table 1, under the optimized conditions, the recovery of six experiments varied from 94.47% to 100.99%. Finally, the developed method was used to determine the content of rutin in Flos Sophorae Immaturus. 10 g Flos Sophorae Immaturus was added in 25 times volume of water and decocted 3 times. The combined filtrate was concentrated and placed over night. Subsequently, the solution was filtrated under vacuum to obtain the initial extracted rutin. 0.067 g accurately weighed rutin extract was dissolved in ethanol and quantified in a 10 mL volumetric flask. Finally, 50 μL solution was added into 10 mL PBS (pH=4). The results are shown in Table 2.
Table 1

Determination of rutin in rutin tablets.

No.Sampling amount (mg)Detected (mg)Recovery (%)
Sample 120.619.795.63
Sample 220.220.4100.99
Sample 320.420.198.53
Sample 420.019.597.50
Sample 519.919.497.49
Sample 619.918.894.47
Table 2

Determination of rutin in Flos Sophorae Immaturus.

No.Detected (%)
Sample 113.39
Sample 214.27
Sample 311.79
Sample 412.29
Sample 511.75
Sample 613.65
Determination of rutin in rutin tablets. Determination of rutin in Flos Sophorae Immaturus.

Conclusion

In this study, a Chit/G/GCE has been introduced and the content of rutin in Flos Sophorae Immaturus has been determined with this modified electrode. The proposed sensor exhibited an excellent electrochemical activity for the reduction and oxidation of rutin and the electrode process was controlled by absorption effect under low scan rate. This sensitive and rapid method for the measurement of rutin proves that the good matrix structure of Chit contributes to the water-solubility of G and that the concentration of rutin adhered on the Chit/G/GCE is increased and the electrochemical response is enhanced rapidly owing to the amino group of Chit.
  10 in total

1.  Electrochemical behavior of rutin on a multi-walled carbon nanotube and ionic liquid composite film modified electrode.

Authors:  Xiuhui Liu; Li Li; Xueping Zhao; Xiaoquan Lu
Journal:  Colloids Surf B Biointerfaces       Date:  2010-07-21       Impact factor: 5.268

2.  Far infrared-assisted extraction followed by capillary electrophoresis for the determination of bioactive constituents in the leaves of Lycium barbarum Linn.

Authors:  Haotian Duan; Yi Chen; Gang Chen
Journal:  J Chromatogr A       Date:  2010-07-02       Impact factor: 4.759

3.  The effect of rutin in experimental malignant hypertension.

Authors:  H K HELLERSTEIN; J L ORBISON; S RODBARD; M WILBURNE; L N KATZ
Journal:  Am Heart J       Date:  1951-08       Impact factor: 4.749

4.  Investigating noncovalent interactions of rutin-serum albumin by capillary electrophoresis-frontal analysis.

Authors:  Qin-hua Lu; Chun-dan Ba; Dong-ying Chen
Journal:  J Pharm Biomed Anal       Date:  2008-03-15       Impact factor: 3.935

5.  Determination of rutin in human plasma by high-performance liquid chromatography utilizing solid-phase extraction and ultraviolet detection.

Authors:  K Ishii; T Furuta; Y Kasuya
Journal:  J Chromatogr B Biomed Sci Appl       Date:  2001-08-05

6.  Development of a biosensor based on gilo peroxidase immobilized on chitosan chemically crosslinked with epichlorohydrin for determination of rutin.

Authors:  Inês Rosane W Zwirtes de Oliveira; Suellen Cadorin Fernandes; Iolanda Cruz Vieira
Journal:  J Pharm Biomed Anal       Date:  2006-02-02       Impact factor: 3.935

7.  Anti-inflammatory effect of rutin on rat paw oedema, and on neutrophils chemotaxis and degranulation.

Authors:  Laid Selloum; Hamama Bouriche; Chafia Tigrine; Chahra Boudoukha
Journal:  Exp Toxicol Pathol       Date:  2003-03

8.  Antidepressant-like effect of rutin isolated from the ethanolic extract from Schinus molle L. in mice: evidence for the involvement of the serotonergic and noradrenergic systems.

Authors:  Daniele G Machado; Luis E B Bettio; Mauricio P Cunha; Adair R S Santos; Moacir G Pizzolatti; Inês M C Brighente; Ana Lúcia S Rodrigues
Journal:  Eur J Pharmacol       Date:  2008-03-29       Impact factor: 4.432

9.  In vitro anti-HIV and -HSV activity and safety of sodium rutin sulfate as a microbicide candidate.

Authors:  Jian Tao; Qinxue Hu; Jing Yang; Rurun Li; Xiuyi Li; Chengping Lu; Chaoyin Chen; Ling Wang; Robin Shattock; Kunlong Ben
Journal:  Antiviral Res       Date:  2007-04-09       Impact factor: 5.970

10.  Functional graphene oxide as a nanocarrier for controlled loading and targeted delivery of mixed anticancer drugs.

Authors:  Liming Zhang; Jingguang Xia; Qinghuan Zhao; Liwei Liu; Zhijun Zhang
Journal:  Small       Date:  2010-02-22       Impact factor: 13.281

  10 in total
  3 in total

1.  A chitosan grafted mesoporous carbon aerogel for ultra-sensitive voltammetric determination of isoniazid.

Authors:  Chellakannu Rajkumar; Raja Nehru; Shen-Ming Chen; S Arumugam; Raman Sankar
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

2.  Polyphenol oxidase/gold nanoparticles/mesoporous carbon-modified electrode as an electrochemical sensing platform for rutin in dark teas.

Authors:  Tongsheng Zhong; Qianqiong Guo; Zhifang Yin; Xiaoyan Zhu; Rong Liu; Aijuan Liu; Shasheng Huang
Journal:  RSC Adv       Date:  2019-01-15       Impact factor: 3.361

3.  Electrocomposite Developed with Chitosan and Ionic Liquids Using Screen-Printed Carbon Electrodes Useful to Detect Rutin in Tropical Fruits.

Authors:  Lili Muñoz; Verónica Arancibia; Olimpo García-Beltrán; Edgar Nagles; John J Hurtado
Journal:  Sensors (Basel)       Date:  2018-09-04       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.