Literature DB >> 29395584

Arthroscopic Diagnosis of the Triangular Fibrocartilage Complex Foveal Tear: A Cadaver Assessment.

Samir K Trehan1, Lindley B Wall1, Ryan P Calfee1, Tony S Shen1, Christopher J Dy1, Sarah M Yannascoli1, Charles A Goldfarb2.   

Abstract

PURPOSE: To determine whether the arthroscopic hook and trampoline tests are accurate and reliable diagnostic tests for foveal triangular fibrocartilage complex (TFCC) detachment.
METHODS: Wrist arthroscopy was performed on 10 cadaveric upper extremities. Arthroscopic hook and trampoline tests were performed and videos recorded (baseline). The deep foveal TFCC insertion was then sharply detached. Arthroscopic hook and trampoline tests were repeated. Subsequently, the foveal detachment was repaired via an ulnar tunnel technique and the hook test was repeated for a third time. Videos were independently reviewed at 2 time points by 2 fellowship-trained hand surgeons and 1 hand surgery fellow in a randomized and blinded fashion. Hook and trampoline tests were graded as positive or negative. Proportions of categorical variables were compared via 2-tailed Fisher exact test. Inter- and intraobserver reliabilities were assessed via Cohen kappa coefficient.
RESULTS: The sensitivity and specificity of the hook test for foveal detachment diagnosis were 90% and 90%, respectively. There was 90% agreement among all 3 observers for the baseline and foveal detachment hook tests. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the hook test were 0.87 and 0.81, respectively. Seventeen percent of trampoline tests were positive at baseline versus 43% after foveal detachment. The trampoline test had 45% agreement between the 3 observers. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the trampoline test were 0.16 and 0.63, respectively. Following ulnar tunnel repair, 20% of hook tests were positive.
CONCLUSIONS: The hook test is highly sensitive, specific, and reliable for the diagnosis of isolated TFCC foveal detachment. The trampoline test has insufficient reliability to assess foveal detachment. A TFCC foveal repair using an ulnar tunnel technique returns the hook test to baseline. CLINICAL RELEVANCE: The hook test is a sensitive, specific, and reliable test for the diagnosis of isolated TFCC foveal detachment.
Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  TFCC tear; Wrist arthroscopy; foveal tear; triangular fibrocartilage complex

Mesh:

Year:  2018        PMID: 29395584     DOI: 10.1016/j.jhsa.2017.12.017

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Changes in the morphology of the triangular fibrocartilage complex (TFCC) on magnetic resonance arthrography related to disruption of ulnar foveal attachment.

Authors:  Ji Hun Park; Kyung-Sik Ahn; Anseong Chang; Young Woo Kwon; In Cheul Choi; Jong Woong Park
Journal:  Skeletal Radiol       Date:  2019-07-18       Impact factor: 2.199

2.  [Anatomical repair of Atzei-EWAS type 2 triangular fibrocartilage complex injury under wrist arthroscopy].

Authors:  Chengyin Lu; Hailong Zhang; Laifu Zhang; Pengtao Wang; Xiaohui Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-11-15

Review 3.  Narrative Review of Ligamentous Wrist Injuries.

Authors:  Ilana G Margulies; Hope Xu; Jared M Gopman; Matthew D Freeman; Etan Dayan; Peter J Taub; Eitan Melamed
Journal:  J Hand Microsurg       Date:  2021-02-28

4.  Habitual volar dislocation of the ulnar head with a locked distal radioulnar joint after distal radius fracture: A case report.

Authors:  Yuji Tomori; Mitsuhiko Nanno; Shinro Takai
Journal:  Medicine (Baltimore)       Date:  2020-07-17       Impact factor: 1.817

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.